Alarm Codes
Service Code
Family
(Platform specific)
Reason
Type
User visible
User
indication
failure
code read
Action in case of failure happens
Dishwashers before
March 2017
User indication
00
Zero cross or low voltage
stop
No
Nothing
i00
User interface off & remaining time adaptation off
Nothing
10
Fill_D – static fill level
ack
Yes
i10
i10
Cycle pause and request to user to confirm to re-start
i10
Fill – re-fill level
ack
Yes
i11
i11
Cycle pause and request to user to confirm to restart
i10
20
Draining problem
ack
Yes
i20
i20
Cycle pause and request to user to confirm to re-start
i20
30
Aqua Control
stop
Yes
i30
i30
Cycle stop and continuous automatically after problem solved – rta off
i30
40
Analogue pressure
-
no signal
abort
Yes
i40
i41
Cycle will be terminated, electronic stop after on/off or failure solved
electronic will switched to reset on-condition
i40
Pressure Sensor Calibration
-
signal too noisy
warning
No
Nothing
i42
Old calibration will be used, cycle continues
Nothing
Analogue pressure
-
signal too high
abort
Yes
i43
i43
Cycle will be terminated, electronic stop after on/off or failure solved
electronic will switched to reset on-condition
i40
Analogue pressure
-
signal too low
abort
Yes
i44
i44
Cycle will be terminated, electronic stop after on/off or failure solved
electronic will switched to reset on-condition
i40
Pressure Sensor Calibration
-
signal too low
warning
No
Nothing
i45
Old calibration will be used, cycle continues
Nothing
Pressure Sensor Calibration
warning
No
Nothing
i46
Old calibration will be used, cycle continues
Nothing
50
AC Wash pump tsc
abort
Yes
i51
i51
Cycle will be terminated and electronic switched to reset on-condition
i50
WP BLDC over current HW
abort
Yes
i52
i52
Cycle will be terminated and electronic switched to reset on-condition
i50
WP BLDC over current SW
abort
Yes
i53
i53
Cycle will be terminated and electronic switched to reset on-condition
i50
WP BLDC motor not following
abort
Yes
i54
i54
Cycle will be terminated and electronic switched to reset on-condition
i50
BLDC under voltage
stop
Yes
i55
i55
Cycle stop and continuous automatically after probl. Solved – rta off
i50
BLDC over voltage
stop
Yes
i56
i56
Cycle stop and continuous automatically after probl. Solved – rta off
i50
(PB100 only)
DP ADC fault
abort
Yes
i57
i57
Cycle will be terminated and electronic switched to reset on-condition
i50
Please OBSERVE that i57 has different meaning depending on platform
(DIVA2 only)
DCLink plausibility error
abort
Yes
i57
i57
Cycle will be terminated and electronic switched to reset on-condition
i50
Technical Support – A.R.
Chapter
4
599 79 76 - 53 REV 1.0