WT38 MED
Prog. 032
CY3
Cycle 3 parameters family.
Ln3
8
Long Wash Phase [min]
Sh3
35
Short Wash Phase [s]
pA3 5
Pause [s]
ri3
35
Rinse Phase Duration [s]
dr3
40
Drain [s]
FP3 60
Final Pause at End of Cycle [s].
dPA
Set other parameters.
rPA
45
Duration of pause after the rinse cycle [s].
6. Switch OFF and then switch ON the machine.
LS6MCD Prog.
033
1.
Switch OFF and then switch ON the machine.
2.
CFG
Enter into CFG parameter family and set the following parameters.
tYP 0
Hood Type like working cycles.
boi 0
Atmospheric boiler.
doo 2
Front loading.
dFL 3
Default values for Undercounter models.
trc 1
SOFT START ENABLED.
b_t 1
Tank heater works only if boiler temperature reached.
btF 75
Enable filling tank by means of rinsing cycles.
LES 1
Detergent level switches enabled.
UI 9
Select user interface hood type model
(up to version 3.11 set to
1
)
.
rE 0
Regeneration cycle disabled.
ALr 1
Alarms enabled.
3.
Switch OFF and then switch ON the machine.