Electrolux
EFS – Dishwashing Systems Platform
Electrolux Professional
Electronic Dishwasher
SERVICE MANUAL
DOC. NO. 5956.446.06
©Copyright 2005 by
Electrolux Professional
P.8/88
5.
COUNTERS
This Parameter Family collects cycle counters and water consumption counters.
For water consumption counters a flow meter must be installed. See
PPL
(calibration parameter) into
dPA
section (§ Other Parameters).
Cnt
Counters
Sym. Parameter
Description
Unit Min Max
Factory
Default
CYC
Cycles performed counter.
CYC
symbol and two numbers blink consecutively. The cycle number is
obtained by joining the two numbers. Ex.
CYC
→
10
→
042
means
10042 cycles executed.
-
cYc
Cycle counter (resettable).
This counter is similar to
CYC
but is resettable by user (see
rSt
parameter
below).
-
nnc
Water Consumption. [present up to software version 3.12]
Counts
m
3
of water consumption.
[m
3
]
L
Water Consumption. [present up to software version 3.12]
Counts
litres
of water consumption.
The total consumption is given by adding
nnc
[m
3
] and
L
[l] values.
[l]
Lit
Water Consumption: resettable counter. [present up to software version 3.12]
Counts the litres of water and is resettable by user (see
rSt
parameter below).
[l]
rSt
Reset resettable counters:
cYc
and
Lit
To reset put 1 this parameter, switch off and then on again:
cYc
and
Lit
will show zero. Note that
cYc
is used to count cycles for
CAll
message
(see next parameter,
nCY
).
-
nCY
Store thousand of cycles after that
CAll
message appears on display.
Ex. If this parameter is settled to 20,
CAll
message appears when
cYc
reach 20.000 cycles.
-
drn
Drain/Cleaning cycles performed.
Similar to
CYC
but counts Cleaning Cycles.
-
rCY
Numbers of cycles that can be made after a regeneration cycle (only for
dishwashers with non-continuous water softener) [See paragraph 9.1 resin
regeneration cycle.].
-
20
NRE
Regeneration cycle counter (only for water softener dishwasher)
[See paragraph 9.1 resin regeneration cycle / paragraph 9.4 Dishwashers with
incorporated continuous water softener].
-
Fig.4.2
Next Family
GEn
Fig. 4.3
Counters Fam.:
ENTER
Cnt
Fig. 4.4
CYCLES
CYC
Fig.4.1
USER setting mode
(press for 5s)
GEn
Fig. 4.5
Thousand.
010
Fig. 4.6
Units.
042
Fig. 4.7
Next counter.
cYc