For kitchen unit installer

Attention: The air outlet must not be connected
to chimney flues or combustion gas ducts. The
air outlet must under no circumstances be
connected to ventilation ducts for rooms in
which fuel-burning appliances are installed.
• When used as an extractor unit, the hood

must be fitted with a  150mm diameter hose.

• When installing the hood, make sure you

respect the following minimum distance
from the top edge of the cooking hob/ring
surfaces:
electric cookers

600 mm

gas cookers

750 mm

coal and oil cookers

850 mm min.

• If the cooker hood is operating in the suction

version concurrently to other combustion
appliances you will need to ensure that the
depression in the environment of these instal-
lations does not exceed the 4PA (4x10

-5  

bar).

• The air outlet must not be connected to

chimney flues or combustion gas ducts. The
air outlet must under no circumstances be
connected to ventilation ducts for rooms in
which fuel-burning appliances are installed.

• It is advisable to apply for authorization from

the relevant controlling authority when
connecting the outlet to an unused chimney
flue or combustion gas duct.
The air outlet installation must comply with
the regulations laid down by the relevant
authorities.

• When the unit is used in its extractor version,

a sufficiently large ventilation hole must be
provided, with dimensions that are approxi-
mately the same as the outlet hole.

• National and regional building regulations

impose a number of restrictions on using
hoods and fuel-burning appliances connected
to a chimney, such as coal or oil room-
heaters and gas fires, in the same room.

• Since the rule for rooms with fuel burning

appliances is “outlet hole of the same size as
the ventilation hole”, a hole of 500-600 cm

2

,

which is to say a larger hole, could reduce
the performance of the extractor hood.

• If the hood is used in its filtering function, it

will operate simply and safely in the above
conditions without the need for any of the
aforementioned measures.

• When the hood is used in its extractor func-

tion, the following rules must be followed to
obtain optimal operation:

— short and straight outlet hose
— keep bends in outlet hose to a minimum
— never install the hoses with an acute

angle, they must always follow a gentle
curve only

— keep the hose as large as possible (prefer-

ably the same diameter as the outlet hole).

• Failure to observe these basic rules will

drastically reduce the performance and
increase the noise levels of the extractor
hood.

For user

• Always cover lighted elements, to prevent

excess heat from damaging the appliance.  In
the case of oil, gas and coal fired cookers it is
essential to avoid open flames.

• Also, when frying, keep the deep frying pan

on the cooker top/cooker under careful
control.

• The hot oil in the frying pan might ignite due

to overheating.

• The risk of self-ignition increases when the

oil being used is dirty.

• It is extremely important to note that over-

heating can cause a fire.

• Never carry out any flambé cooking under

the hood.

• Always disconnect the unit from the power

supply before carrying out any work on the
hood, including replacing the light bulb
(take the cartridge fuse out of the fuse holder
or switch off the automatic circuit breaker).

• It is very important to clean the hood and

replace the filter at the recommended
intervals. Failure to do so could cause
grease deposits to build up, causing a fire
hazard.

Summary of Contents for EFC 009.1X

Page 1: ...Gebrauchsanweisung Manuel d utilisation EFC 009 1X F I D Istruzioni per l uso User manual UK ...

Page 2: ...rease filter 36 Warning 36 Carbon filter 37 Changing the light bulb 37 Technic Details 38 Special accessories 38 Installation 38 Unpacking 38 Placement 38 Electrical connection 38 Mounting of hood 39 Before you use the cooker hood we recommend that you read through the whole user manual giving a direct description of the cooker hood and its functions To avoid the risks that are always present when...

Page 3: ...s and gas fires in the same room Since the rule for rooms with fuel burning appliances is outlet hole of the same size as the ventilation hole a hole of 500 600 cm2 which is to say a larger hole could reduce the performance of the extractor hood If the hood is used in its filtering function it will operate simply and safely in the above conditions without the need for any of the aforementioned mea...

Page 4: ...filter Fig 1 Function The hood may be used as follows Extractor version Filter version Extractor version The air is vented outdoors by a duct A Ø150 mm Fig 2 which must be connected to connecting ring on top of the motor pack age Filter version The air is filtered through an activated charcoal filter and returned to the kitchen through the top grill of the outlet pipe fig 3 This version is used wh...

Page 5: ...h warns you when to clean the grease filter or replace the carbon filter in the case of the air recircultion version This hood is delivered without a carbon filter For this reason the warning signal to replace the carbon filter is not connected If the hood will be used for recirculation of air with carbon filter the warning signal have to be connected as follows Press the buttons B and G at the sa...

Page 6: ...sher every four weeks Open the metal grease filter Pull the handles backwards to loosen the filter Fig 4 Hand washing Soak grease filters for about one hour in hot water with a grease loosening cleaner then rinse off thoroughly with hot water Repeat the process if necessary Refit the grease filters when it are dry Dishwasher machine Place grease filters in dish washer Select most powerful washing ...

Page 7: ...ear The active carbon filter should not be washed under any circumstances In order to substitute the filter remove the screws fig 5 and slide the filter downwards Note the activated carbon filter must normally be replaced at least once a year This filter cannot be washed or regenerated To guarantee proper absorption of odours the working vol ume of the activated carbon must be proportion ate to th...

Page 8: ...ithin easy access Should it be necessary to provide a fixed con nection the hood must only be installed by an electrician authorised by the local electricity Min 75cm Min 60cm Technic Details Model EFC 009 1 Dimensions height 752 930 mm width 1000 mm depth 700 mm Lighting 4 x 20 W Grease filter 2 max absorbed power 240 W We reserve the right to generate constructive and chromatic modifications as ...

Page 9: ...the height of the body of the hood is 290 and that a minimum distance from hobs must be in any case respected see paragraph Placement Choose how to use the hood Extractor version Fit a Ø 150 mm exhausting pipe or flex tube on the ceiling sufficiently long to reach the connection ring above the hood once the hood will be fit on place Recirculating version Fit the deflector from one side of the slot...

Page 10: ... Sides with fixing points c for the external telescopic chimney correspond to the right and left sides fig 8 The hood is supplied with installation fit tings suitable for most kinds of ceilings but in any case a qualified installation techni cian must be consulted in order to choose the best mounting solution Fix the upper and lower part of the utter chimney together temporarily with one screw a 2...

Page 11: ...ely thighten the nuts b Fig 13 Secure the hood with one screw 4x9 5 C Fig 13 Fit the electrical plug to the power outlet Remove the screw that fix the two parts of the utter chimney together Slide the lower part of the chimney down wards and insert it on its proper housing on the upper side of the hood Fig 14 Mounting of carbon filter for filter version Remove the grease filter Fix the carbon filt...

Page 12: ......

Page 13: ......

Page 14: ...hberatung Verkauf Demonstration Vente Consulente cucina Vendita 8048 Zürich Badenerstrasse 587 Tel 01 405 81 11 8048 Zürich Badenerstrasse 587 Tel 01 405 81 11 8048 Zürich Badenerstrasse 587 Tel 01 405 81 11 Garantie Garantie Garanzia Wir gewähren auf allen Produkten die in der Schweiz gekauft und in Betrieb sind eine einjährige Vollgarantie gerechnet ab Lieferdatum an den Endver braucher Massgebe...

Reviews: