background image

This appliance conforms to European Low Voltage Directive 73/23/CEE governing electrical safety, European Directive 89/
336/CEE on Electromagnetic Compatibility and Directive 93/68/CEE regarding CE Marking.

Este aparato es conforme con la normativa europea sobre baja tensión C.E.E. 73/23 correspondiente a la seguridad eléctrica
y a las normativas europeas : C.E.E. 89/336 sobre la compatibilidad electromagnética y C.E.E. 93/68 sobre la marca CE.

Dieses Gerät entspricht folgenden EG-Richtlinien: Niederspannungsrichtlinie EWG 73/23 hinsichtlich elektrischer Sicher-
heit, Richtlinie Elektromagnetische Verträglichkeit EWG 89/336 und Richtlinie EWG 93/68 hinsichtlich der CE-Kennzeich-
nung.

Este aparelho está em conformidade com a norma europeia acerca da baixa tensão C.E.E. 73/23, respeitante à segurança
eléctrica e com as normas europeias: C.E.E. 89/336 respeitante à compatibilidade electromagnética e C.E.E. 93/68 respeitante
à marcação CE.

436002073_01 - 040204

Summary of Contents for EFC 1540

Page 1: ...Instruction Manual Manual de instrucciones Bedienungsanleitung Manual de Instruções PT 30 DE 21 ES 12 GB 3 EFC 6540 EFC 7540 EFC 9540 EFC 1540 ...

Page 2: ......

Page 3: ... recommendations contained in this Instruction Manual your appliance will give you constant high per formance and will remain efficient for many years to come RECOMMENDATIONS AND SUGGESTIONS 4 CHARACTERISTICS 5 INSTALLATION 6 USE 9 MAINTENANCE 10 ...

Page 4: ...ent degree of aeration must beguaranteedintheroominordertopreventthebackflowofexhaust gas The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells Never use the hood for purposes other than for which it has ben designed Neverleavehighnakedf...

Page 5: ...Flange ø 150 120 mm 14 1 2 AirOutletConnectionExtension 15 1 AirOutletConnection Ref Q ty Installation Components 7 2 1 2 Upper Chimney Section Fixing Brackets 7 3 1 AirOutletConnectionSupport 11 6 WallPlugs 12a 6 Screws 4 2 x 44 4 12c 6 Screws 2 9 x 9 5 Q ty Documentation 1 InstructionManual 1 Warranty 740 870 1200 260 300 64 42 650 min 490 60 598 898 108 150 2 1 2 2 2 12c 12a 7 2 1 11 11 12a 1 9...

Page 6: ...e first bracket X height of the upper chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes in the bracket Mark a reference point as indicated at 116 mm from the vertical reference line and 320 mm above the horizontal reference line Repeat this operation on the other side Drill ø 8 mm holes at all the centre points marked Insert the wal...

Page 7: ...onnection insert the reducer flange 9 on the hood body outlet Fix the pipe in position using sufficient pipe clamps not supplied Remove any activated charcoal filters RECIRCULATION VERSION AIR OUTLET Put connection 15 into the connection support 7 3 Insert the connection extension pieces laterally 14 1 in connection 15 Make sure that the outlet of the extension pieces 14 1 is horizontally and vert...

Page 8: ...haust flue Slightly widen the two sides of the upper flue andhook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets using the 4 screws 12c 2 9 x 9 5 supplied Make sure that the outlet of the extensions pieces is aligned with the chimney outlets Lower exhaust flue Slightly widen the two sides of the flue and hook thembetweentheupperflueandthewall ...

Page 9: ... for about 2 seconds After 10 minutes of functioning it turns off automatically This function can be interrupted by means of pressing any of the buttons S1 Led Fixed Indicates that the Metal grease filters saturation alarm has been triggered and the filters need to be washed The alarm is triggered after 100 working hours Reset check the Maintenance paragraph Flashing indicates that the activated c...

Page 10: ...e refitting When refitting the filters make sure that the handle is visible on the outside Activated charcoal filter Recirculation version REPLACING THE ACTIVATED CHARCOAL FILTER Alarm signal activation In Recirculation version Hoods the Filter saturation alarm can be enabled on installation or at a later date Turn the Lights and the suction Motor off Disconnect the Hood using the Main switch or t...

Page 11: ...Filter Remove the metal grease filters Remove the saturated activated carbon filter by releasing the fixing hooks Fit the new filter by hooking it into its seating Replace the metal grease filters Lighting LIGHT REPLACEMENT 20 W halogen light Removethe2ScrewsfixingtheLightingsupport and pull it out of from the Hood Extract the Lamp from the Support Replace with another of the same type making sure...

Page 12: ...a compatibilidad electromagnética y C E E 93 68 sobre la marca CE Dieses Gerät entspricht folgenden EG Richtlinien Niederspannungsrichtlinie EWG 73 23 hinsichtlich elektrischer Sicher heit Richtlinie Elektromagnetische Verträglichkeit EWG 89 336 und Richtlinie EWG 93 68 hinsichtlich der CE Kennzeich nung Este aparelho está em conformidade com a norma europeia acerca da baixa tensão C E E 73 23 res...

Reviews: