48
Technical Specifications
Installation
Unpacking
Check that the cooker hood has no damages.
Transportation damages should immediately be
reported to the company responsible for the
transportation.
Damages, faults and eventually missing details should
immediately be reported to the retailer.
Take care of the packing materials so that small
children cannot play with them.
Fitting
The hood is to be mounted on the wall.
When installed, the hood must be not less than 50 cm.
above electric burners or 65 cm. above gas or mixed-
fuel burners.
The hood can be installed above these heights but for
optimum performance it should be installed at the
distance quoted for the appropriate heat source.
Electrical connection (not for UK)
Safety warnings for the electrician
Before connecting the appliance to the power supply,
check that the voltage indicated on the rating plate
corresponds to the mains power supply available.
Appliances fitted with a plug can be connected to any
standard power socket within easy access.
Should it be necessary to provide a fixed connection,
the hood must only be installed by an electrician
authorised by the local electricity board. When
installing, an omnipolar disconnector with a distance
of at least 3 mm between contacts must be provided.
Fixed connection of the appliance must only be
carried out by an authorised electrician.
Electrical connection for UK
only
Safety warnings for the electrician
Connect the hood to the mains supply via a double
pole switch which has 3 mm minimum separation
between the contacts.
The switch must be accessible at all times.
The following is valid in the United Kingdom only:
- the wire which is coloured green and yellow
must be connected to the terminal which is
marked with the letter E or by the earth symbol
( ), or coloured green or green and yellow;
- the wire which is coloured blue must be
connected to the terminal which is marked with
the letter N or coloured black, -
- the wire which is coloured brown must be
connected to the terminal which is marked with
the letter L or coloured red.
Fig. 7 - Fitting
Min
65 cm
Min
50 cm
Model:
EFC 9404
EFC 6404
EFC 9412
EFC 6412
EFC 9408
Dimensions (in cm):
Height (Filter Version) 82-127,5(82-137)
82-125,5(80-135)
82-127,5(82-137) 82-125,5(80-135)
82-127,5(82-137)
Width
89,8
59,8
89,8
59,8
89,8
Depth
48
48
48
48
48
Max. absorbed power:
290 W
290 W
180 W
180 W
290 W
Motor absorption:
250 W
250 W
170 W
170 W
250 W
Lighting:
2 x 20 W
2 x 20 W
11 W
11 W
2 x 20 W
Length of the cable:
150 cm
150 cm
150 cm
150 cm
150 cm
Electrical connection: 220-240 V
220-240 V
220-240 V
220-240 V
220-240 V
Subject to change without notice.