background image

6

If the hood does not function

Before calling for service

Check the plug is correctly connected to the wall socket.
Check the fuse. Do not attempt any repairs yourself that are
likely to lead to further damage. If the problem remains,
contact your dealer or an approved service company.
Remember to save your purchase receipt and warranty card
(only used in some countries).

Service and spare parts

Your dealer or service company will supply you with service
and spare parts. Be sure you have the product number and
model name at hand when ordering service or parts.

Technical data

Model

EFC 928 X

Size

Height

800-1340 mm

Width

898 mm

Depth

510  mm

Light

Max 2x11 W

Grease filter

3 pcs.

Voltage

230 V

Total power

185 W

Installation

Position

The cooker hood should be mounted freely hanging on the
wall. The cooker hood must be at least 50 cm above electric
burners or electric range, or at least 75 cm above gas
burners or gas range.

Unpacking

Check that the cooker hood is not damaged. Transportation
damages should immediately be reported to the transport
company. Damages, faults and eventually missing parts
should immediately be reported to the retailer. Dispose
carefully of the packaging material so that it is out of the
way of small children.

Electrical connection

The electric outlet should be placed inside the chimney. The
hood has a power cord and moulded plug with earth
connection for a wall outlet of 230V.

Summary of Contents for EFC 928

Page 1: ...User Manual EFC 928 GB ...

Page 2: ...r hood must be at least 50 cm above electric burners or electric range or at least 75 cm above gas burners or gas range Ensure that the power cord does not get squeezed at the installation The cooker hood is only dead when the plug or the fuse is disconnected The cooker hood cannot be connected to flues of other appliances that run on energy sources other than electricity Please keep to the provis...

Page 3: ...sing optional venting kit and evacuation duct Recirculation using carbon filter Exhausting version The air is vented outdoors by a 150 mm duct which must be connected to connecting ring with no return valve on top of the motor package The cooker hood cannot be connected to flues of other appliances that run on energy sources other than electricity Please keep to the provisions of official directiv...

Page 4: ...Best results are obtained by using low speed for normal conditions and high speed when smells and steam are more concentrated Turn the hood on a few minutes before you start cooking then you will get an underpressure in the kitchen It should be left on after cooking for about 15 minutes or until all steam and smells have disappeared The control panel is located on the front right side Decrease fan...

Page 5: ...ctivate the carbon the filter should be dried in an oven for 10 minutes with a temperature of maximum 100ºC After approximately three years of use the TYPE 23 filter should be replaced with a new as the odour reduction capacity will be reduced Mounting the carbon filter Fig 2 Unplug the unit or disconnect it from the power supply Remove the metal grease filters Fig 1 Unscrew the two carbon filter ...

Page 6: ...ght 800 1340mm Width 898 mm Depth 510 mm Light Max2x11W Grease filter 3 pcs Voltage 230V Total power 185W Installation Position The cooker hood should be mounted freely hanging on the wall The cooker hood must be at least 50 cm above electric burners or electric range or at least 75 cm above gas burners or gas range Unpacking Check that the cooker hood is not damaged Transportation damages should ...

Page 7: ...ews on the hooks Fig 4 The reference point a marked on the body of the extractor hood must coincide with the line you have drawn on the wall Fig 4 Once the extractor hood has been correctly aligned remove the grease filter From inside the hood mark the final points at which the hood has to be fixed to the wall Fig 5 to reach these points it will be necessary to remove activated carbon filter frame...

Page 8: ...rating mode Extractor operation Fix the 150 mm diameter ABS pipe to the hood outlet and ensure that the other end discharges into the open air Filter operation If the connector ring has not yet been installed it must be fitted at this point Q in Fig 7 bayonet connector Turn it in a clockwise direction and fix it to the air pipe L using a screw Insert the air pipe into the telescopic chimney suppor...

Page 9: ...9 ...

Page 10: ...10 ...

Page 11: ...11 ...

Page 12: ...LI1REA Ed 06 01 ...

Reviews: