Safety warnings

for the installer

When used as an extractor unit, the hood must
be fitted with a  150mm diameter hose.
Should there already be a pipe of diameter 125
mm that ducts to the outside through the walls
or roof, it is possible to use the 150/125 mm
reduction flange provided. In this case the hood
will be slightly more noisy.

When installing the hood, make sure you
respect the following minimum distance
from the top edge of the cooking hob/ring
surfaces:
electric cookers

600 mm

gas cookers

750 mm

coal and oil cookers

800 mm min.

The national standard on fuel-burning systems
specifies a maximum depression of 0.04 bar in
such rooms.

The air outlet must not be connected to chimney
flues or combustion gas ducts. The air outlet
must under no circumstances be connected to
ventilation ducts for rooms in which fuel-burning
appliances are installed.

It is advisable to apply for authorization from the
relevant controlling authority when connecting
the outlet to an unused chimney flue or
combustion gas duct.
The air outlet installation must comply with the
regulations laid down by the relevant authorities.

When the unit is used in its extractor version, a
sufficiently large ventilation hole must be
provided, with dimensions that are
approximately the same as the outlet hole.

National and regional building regulations
impose a number of restrictions on using hoods
and fuel-burning appliances connected to a
chimney, such as coal or oil room-heaters and
gas fires, in the same room.

Hoods can only be used safely with appliances
connected to a chimney if the room and/or flat
(air/environment combination) is ventilated from
outside using a suitable ventilation hole approxi-
mately 500-600 cm

 large to avoid the

possibility of a depression being created during
operation of the hood.

If you have any doubts, contact the relevant
controlling authority or building inspector’s
office.

Since the rule for rooms with fuel burning
appliances is “outlet hole of the same size as the
ventilation hole”, a hole of 500-600 cm

2

, which

is to say a larger hole, could reduce the perfor-

mance of the extractor hood.

If the hood is used in its filtering function, it will
operate simply and safely in the above
conditions without the need for any of the
aforementioned measures.

When the hood is used in its extractor function,
the following rules must be followed to obtain
optimal operation:
— short and straight outlet hose
— keep bends in outlet hose to a minimum
— never install the hoses with an acute angle,
they must always follow a gentle curve only
— keep the hose as large as possible
(preferably the same diameter as the outlet
hole).

Failure to observe these basic instructions will
drastically reduce the performance and increase
the noise levels of the extractor hood.

for the user

The cooker hood is designed to extract
unpleasant odours from the kitchen, it will not
extract steam.

Always cover lighted elements, to prevent
excess heat from damaging the appliance.  In
the case of oil, gas and coal fired cookers it is
essential to avoid open flames.

Also, when frying, keep the deep frying pan on
the cooker top/cooker under careful control.

The hot oil in the frying pan might ignite due to
overheating.

The risk of self-ignition increases when the oil
being used is dirty.

It is extremely important to note that
overheating can cause a fire.

Never carry out any flambé cooking under
the hood.

Always disconnect the unit from the power
supply before carrying out any work on the
hood, including replacing the light bulb
(take the cartridge fuse out of the fuse holder or
switch off the automatic circuit breaker).

It is very important to clean the hood and
replace the filter at the recommended
intervals. Failure to do so could cause
grease deposits to build up, resulting in a
fire hazard.

The appliance is not intended for use by young
children or infirm persons without supervision.

Young children should be supervised to ensure
that they do not play with the appliance.

WARNING - Ensure that the appliance is
switched off before replacing the lamp to avoid
the possibility of electric shock.

Summary of Contents for EFC 9460

Page 1: ...Gebrauchsanweisung Notice d utilisation et d installation EFC 9460 F NL D Installatie en gebruiksaanwijzing User manual UK ...

Page 2: ...chnical Specifications 32 Special accessories 32 Installation 32 Unpacking 32 Placement 32 Electrical connection 32 Mounting accessories included 33 Wall unit mounting 33 UK Before you use the cooker hood we recommend that you read through the whole user manual giving a direct description of the cooker hood and its functions To avoid the risks that are always present when you use a product driven ...

Page 3: ...appliances is outlet hole of the same size as the ventilation hole a hole of 500 600 cm2 which is to say a larger hole could reduce the perfor mance of the extractor hood If the hood is used in its filtering function it will operate simply and safely in the above conditions without the need for any of the aforementioned measures When the hood is used in its extractor function the following rules m...

Page 4: ...in the best performance the hose should have a diameter equal to the outlet hole Should there already be a pipe of diameter 125 mm that ducts to the outside through the walls or roof it is possible to use the 150 125 mm reduction flange provided In this case the hood will be slightly more noisier Fig 1 Filter Version The air is filtered through a charcoal filter and returned to the kitchen through...

Page 5: ...__________________ Product number ________________________ Date of purchase ________________________ The hood is fitted with one motor having several speed Turn the hood on a few minutes before you start cooking you will then get an under pressure in the kitchen The hood should be left on after cooking for about 15 minutes or until all the odours have disappeared The control switches are located o...

Page 6: ...e grease filters is to aspirate grease particles which form during cooking and it must always be used either in the external evacuation or internal recycling function Attention the metal grease filters must be removed and washed either by hand or in the dishwasher every four weeks Open the metal grease filter Pull out the spring lock to release the grease filter Fig 4 Hand washing Soak grease filt...

Page 7: ...pproximately three years of use the carbon filter should be replaced with a new as the odour reduction capacity will be reduced Mounting Remove the frame i which supports the filter h by turning 90 the two knobs g Fig 5 Insert the charcoal mattress inside the frame and put all parts back in their place To dismount proceed in reverse order Always specify the hood model code number and serial number...

Page 8: ... the voltage indicated on the rating plate corresponds to the mains power supply available Appliances fitted with a plug can be connected to any standard power socket within easy access Should it be necessary to provide a fixed connection the hood must only be installed by an electrician authorised by the local electricity board When installing an omnipolar disconnector with a distance of at least...

Page 9: ...ounted 5 Drill two holes Ø 8mm and fix the support bracket with two wall plugs and screws 6 Hang the hood 7 adjust its position 8 9 and from the inside of the hood sign one point for definitive fixing 10 remove the hood 11 and drill an hole Ø 8mm 12 fit a wall plugs 13 Drill two holes Ø 8mm on the upper side close to the ceilling 14 fit two wall plugs and fix the chimney support with two screws 15...

Page 10: ...LI1X8C Ed 09 02 ...

Reviews: