background image

We were thinking of you

when we made this product

Summary of Contents for EFC90950

Page 1: ...USER MANUAL EFC90950 ...

Page 2: ...We were thinking of you when we made this product ...

Page 3: ... will provide you with lots of pleasure in the future The Electrolux ambition is to offer a wide variety of quality products that make your life more comfortable You find some examples on the cover in this manual Please take a few minutes to study this manual so that you can take advantage of the benefits of your new machine We promise that it will provide a superior User Experience delivering Eas...

Page 4: ...self when the fan motor has cooled significantly It is dangerous to alter the specifications or modify this product in any way When installed between adjoining wall cabinets the wall cabinets must not overhang the hob If the room where the hood is to be used contains a fuel burning appliance such as a central heating boiler then its flue must be of the room sealed or balanced flue type If other ty...

Page 5: ...YOUR APPLIANCE AND OPERATING INSTRUCTIONS electrolux 5 EN YOUR APPLIANCE 650 min ...

Page 6: ...est cooking vapours and odours The function becomes active when the button is pushed for about 2 seconds After 10 minutes of functioning it turns off automatically This function can be interrupted by means of pressing any of the buttons S1 Led Fixed Indicates that the Metal grease filters saturation alarm has been triggered and the filters need to be washed The alarm is triggered after 100 working...

Page 7: ...ough the grease filters and is passed out through the ducting into the atmosphere To obtain the best performance when cooking it is advisable to switch the cooker hood on for a few minutes before you start cooking and leave it running for about 15 minutes after finishing When used in the ducting mode the charcoal filters are not required Never do flambé cooking under this cooker hood Never leave f...

Page 8: ... of wa ter when cleaning particularly around the control panel Metal Grease Filters The filters are washable and must be cleaned when the Led S1 lights up or at least every 2 months of operation or more frequently for particularly heavy usage Remove the metal grease filters one at a time by Releasing the catches on the filters the filters can be removed The metal grease filters should be washed by...

Page 9: ...d T4 flash in confirmation LED flashes twice Activated charcoal filter saturation alarm ENABLED LED flashes once Activated charcoal filter saturation alarm DISABLED The filter is not washable and cannot be regenerated It must be replaced when led S1 flashes or at least every 4 months The alarm signal will only light up when the extractor motor is switched on To Remove Replace the Charcoal Filters ...

Page 10: ...pporting it with one hand Remove the halogen lamp from the lamp holder by pulling gently Replace the lamp with a new one of the same type making sure that you insert the two pins properly into the housings on the lamp holder Replace the snap on lamp cover Replacement filters and light bulbs can be obtained from your local Service Force Centre ...

Page 11: ...ntee service calls Solution Check the hood is connected to the electricity supply Make sure the switch is in the ON posi tion The fan speed is set high enough for the task The grease filter is clean The kitchen is adequately vented to allow the entry of fresh air If set up for recirculation check that the charcoal filter is still effective If set up for extraction check that the ducting and outlet...

Page 12: ...y light bulbs or removable parts of glass or plastic Costs incurred for calls to put right an appliance which is improperly installed or calls to appliances outside the United Kingdom Appliances found to be in use within a commercial environment plus those which are subject to rental agreements Products of Electrolux manufacturer that are not marketed by Electrolux Service and Spare Parts In the e...

Page 13: ...ow the appliance guarantee will move with you subject to the following qualifications The appliance guarantee starts from the date you first purchased the appliance which will be evidenced by production of a valid purchase document issued by the seller of the appliance The appliance guarantee is for the same period and to the same extent for labour and parts as exists in your new country of reside...

Page 14: ...va 370 5 2780609 Verkių 29 LT 09108 Vilnius Luxembourg 35 2 42 43 13 01 Rue de Bitbourg 7 L 1273 Hamm Magyarország 36 1 252 1773 H 1142 Budapest XIV Erzsébet királyné útja 87 Nederland 31 17 24 68 300 Vennootsweg 1 2404 CG Alphen aan den Rijn Norge 47 81 5 30 222 Risløkkvn 2 0508 Oslo Österreich 43 18 66 400 Herziggasse 9 1230 Wien Polska 48 22 43 47 300 ul Kolejowa 5 7 Warsaw Portugal 35 12 14 40...

Page 15: ...s appliance complies with the requirements laid down in EEC directive 89 336 Electromagnetic compatibility and subse quent modifications and Low Voltage directive 72 23 E The symbol on the product or on its packaging indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equ...

Page 16: ...ng to the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate inside the cooker hood This appliance is fitted with a 2 core mains cable and must be permanently connected to the electricity supply via a double pole switch having 3mm minimum contact gap on each pole A Switched Fuse Connection Unit to BS1363 Part 4 fitted with a 3 Amp fuse is a recommended mains ...

Page 17: ...r hood is to be fitted for electric cables water pipes or gas This cooker hood is designed to be fixed to any vertical surface over a cooking area and can be used in the extraction ducted to the outside or recirculation mode Theinstallationworkmustbeundertaken by a qualified and competent person The manufacturer disclaims any responsibility for damage due to incorrect installation of the cooker ho...

Page 18: ...c Chimney comprising 2 1 1 Upper section 2 2 1 Lower section 9 1 ø150 120 Ducting spigot 10 1 ø120 125 Ducting flange 14 1 2 Air outlet Connection Extension 15 1 Air outlet Connector Ref Qty Installation Components 7 2 1 2 Upper chimney wall fixing brackets 7 3 1 Air outle Connection Support 12c 6 Chimney fixing screws Ref Qty Documentation 1 Instruction booklet 2 1 2 2 2 12c 7 2 1 1 9 7 3 14 1 15...

Page 19: ...learance height of 685mm 27 is required when installed above a slot in electric cooker or 787mm 30 1 2 when installed above a slot in gas cooker When installed between adjoining wall cabinets the wall cabinets must not overhang the hob and the distance between the underside of the cabinet and the worktop must be 450mm If the height of the wall cabinet is less than 450mm a gap of 50mm must be maint...

Page 20: ...vertical line Mark the wall at the centres of the holes in the bracket Mark a reference point as indicated at 116 mm from the vertical reference line and 310 mm above the horizontal reference line Repeat this operation on the other side Drill ø 8 mm holes at all the centre points marked Insert the wall plugs not supplied in the holes Fix the lower bracket 7 2 1 using the two screws not supplied Fi...

Page 21: ... adjust the screws item Vr until the hood body is level Extraction The cooker hood is more effective when used in the extraction mode ducted to the outside Venting kits may be purchased through your retailer or DIY store and must be ducted to an outside vent of Ø125mm 5 or Ø150mm 6 The ducting used must be manufactured from fire retardent material conforming to the relevant British Standard or DIN...

Page 22: ...circulation duct place the recirculation outlet connection item 15 into the support item 7 3 Insert the extension ducts item 14 1 into either side of the recirculation outlet item 15 ensuring the connections are vertically and horizontally aligned with the outlets in the chimney Connect the recirculation oulet item 15 to the outlet on top of the hood body using either a piece of Ø125mm or Ø150mm f...

Page 23: ...ed in the ducting run If the distance is greater than 3 metres the efficency of the hood could be impaired The diameter of the ducting spigot on the top of the hood body item 1 is Ø150mm 6 When using Ø125mm 5 ducting it will be necessary to install the ducting adapter item 9 to the Ø150mm 6 outlet on the top of the hood body and the Ø120mm to 125mm ducting collar item 10 supplied If the room where...

Page 24: ... Chimney To fit the upper chimney section item 2 1 expand the chimney slightly to allow it to be fitted over the brackets item 7 2 1 as illustrated When installed in the recirculation mode ensure that the recirculation ducting outlet extension pieces item 14 1 align correctly with the outlet grilles in the chimney Secure the sides of the chimney to the brackets using the four screws item 12c 2 9x9...