22 electrolux
INSTALLING THE COOKER HOOD
EN
Recirculation
The cooker hood is supplied speci
fi
ed
for use in the recirculation mode, with
the charcoal
fi
lter
fi
tted.
In the recirculation mode contaminated
air is passed through the charcoal
fi
lter
to be puri
fi
ed and recirculated into the
kitchen through the grille outlets on
either side of the chimney.
To assemble the recirculation duct,
place the recirculation outlet connection
item
15
into the support item
7.3
.
Insert the extension ducts item
14.1
into either side of the recirculation outlet
item
15
ensuring the connections are
vertically and horizontally aligned with
the outlets in the chimney.
Connect the recirculation oulet item
15
to the outlet on top of the hood body
using either a piece of Ø125mm or
Ø150mm
fl
exible or rigid pipe.
Rigid pipe is strongly recommended
and should be used where possible as
this will ensure the best performance
while lowering noise.
14.1
15
7.3
ø 150