installation instructions
electrolux
17
Important: Do not connect down
draught extractor to the voltage
supply until an adequate air outlet
has been provided.
Do not connect vent hose or vent
pipe to an air shaft, flue or similar
which is already in use.
If several Frontline appliances are in-
stalled, install down draught extractor
between the appliances.
Distance from flammable materials: at
least 150 mm
Important: Official regulations must
be followed when drawing off ex-
haust air.
Important: Do not conduct exhaust
air to a chimney which is used by
appliances operated with gas or
other combustible fuels.
Installing next to a gas appliance
Important: The appliance must not be
built in between two gas appliances.
Important: If a gas appliance is in-
stalled next to the down draught ex-
tractor, the down draught extractor
may only extract air on the opposite
side. Therefore the fin nearest the
gas appliance must be removed and
the supplied cover must be fitted.
Summary of Contents for EFD18000U
Page 1: ...user manual Down draught extractor EFD18000U ...
Page 2: ...We were thinking of you when we made this product ...
Page 19: ...assembly electrolux 19 Assembly min 500 mm ...
Page 20: ...20 electrolux assembly ...
Page 25: ...electrolux 25 Rating Plate 941 177 669 230 240 V 0 31 kW FDD 180 EFD18000U 50 Hz ELECTROLUX ...