background image

34

Maintenance and cleaning

Work light

The hood has two PL lamps 9 W.
Switch on and off with the left slide switch.

Correct ventilation

To have the cooker hood working correctly the
windows in the kitchen should be closed. In
stead a window in an adjacent room should be
open (Fig. 11).

Important to know

If the hood is run at the same time as a burner or
fireplace that depend on ambient air (for example
gas, Diesel, coal or wood heaters, water heaters,
etc.) be careful, because the hood, when it
exhausts the air, removes the ambient air re-
quired by the burner or fireplace for combustion.
Not valid if the cooker hood is used in
recirculation mode.

Before performing any maintenance
operation, disconnect the hood from
the electricity.

Grease filter

This serves to hold the grease particles in sus-
pension. The metal filter should be washed every
month with warm soapy water or, if possible, in
the dishwasher (60

°

C).

Remove the filter:

Open the latch A and rotate the grid down-
wards (Fig. 12).

To remove, pull forward from the right hand
side and unhook.

Release the clips F (Fig. 13).

Leave to dry before refitting it.
Grid must be cleaned as well as the grease filter.

Carbon filter

This filter dissolves cooking odours.
It should be changed every 6-8 months in normal
use. Ask the technical assistance service or
manufacturing company for a new one.
The carbon filter must never be washed.
To remove the carbon filter, push the hooks C
and pull the filter downwards (Fig. 9).

Fig. 11

A

Fig. 12

Fig. 13

F

Summary of Contents for EFT 629

Page 1: ...Gebrauchsanweisung Manuel d utilisation EFT 629 EFT 929 Gebruiksaanwijzing User Manual UK F D NL ...

Page 2: ... of hood on wall 32 Mounting under cupboard 33 Exhausting mode 33 Recirculation mode with carbon filter 33 Using the hood 33 Speed regulation 33 Work light 34 Correct ventilation 34 Important to know 34 Maintenance and cleaning 34 Grease filter 34 Carbon filter 34 Attention 35 Cleaning 35 Changing the lighting elements 35 If the hood does not function 35 Before you make contact to service 35 Servi...

Page 3: ...roperties The hood cannot be connected to flues of other appliances that run on energy sources other than electricity Please keep to the provisions of official directives regarding the question of fumes discharge When the hood is used at the same time as other appliances that run on energy sources other than electricity provision must be made for an adequate supply of air When installed the hood m...

Page 4: ...return valve bayonet coupling Insert plug H in the unused exhaust hole bayo net coupling Plug H is for closing the unused hole Attention In the horizontal runs the duct must be slightly slanted about 10 and directed upwards to vent the air easily from the room to the out side The hood cannot be connected to flues of other appliances that run on energy sources other than electricity Please keep to ...

Page 5: ...oard When installed the hood must be not less than 60 cm above electric burners or 70 cm above gas or mixed fuel burners Fig 4 Electrical connection The hood has a power cord with moulded plug with earth connection to be connected to a wall outlet of 230 V The power cord length is 1 2 m Mounting of hood on wall Fix the drilling template to the wall Fig 5 Make 3 Ø 8 mm holes in the wall 2 at points...

Page 6: ...lever for evacuation recycle is in the position F recycle Fig 9 Pull both selectors d towards the centre of the appliance Fit carbon filter first rearwards on the proper seats Then fix frontwards the carbon filter using hooks C Fig 9 Refit the suction grid Using the hood Speed regulation The hood is provided with two motors with continues speed regulation plus a position for intensive operation Fo...

Page 7: ... mode Before performing any maintenance operation disconnect the hood from the electricity Grease filter This serves to hold the grease particles in sus pension The metal filter should be washed every month with warm soapy water or if possible in the dishwasher 60 C Remove the filter Open the latch A and rotate the grid down wards Fig 12 To remove pull forward from the right hand side and unhook R...

Page 8: ... you will find on the rating label Take away the grease filter and you will find the rating label behind Model Product number Date of purchase If the hood does not function Attention Failure to observe the rules for cleaning the appliance and changing and cleaning the filters may cause fires Therefore we recommend observing these instructions Cleaning To clean the outside of the hood use a cloth m...

Page 9: ...ion Height 130 mm 130 mm Width 599 mm 899 mm Depth 494 mm 494 mm Light PL lamps 2 x 9 W 2 x 9 W Grease filter 2 pcs 2 pcs Mains Voltage 230 V 230 V Electric safety class Class II Class II Power rating total 270 W 270 W x Valid when the hood is used with carbon filter recirculation 599 120 27 3 42 7 61 98 370 320 340 5 493 5 130 195 65 37 85 599 899 ...

Page 10: ...1007WW L 695 A Ed 12 96 ...

Reviews: