5.
COMBINATION BUTTON AND FUNCTIONS
Child lock
Button Function
Operation
Light intensity
Demo mode
Long press button for 5 seconds to lock all program
gfunctions, lock symbol lights on display, long press 5
seconds again to deactivate.
Long press button for 5 seconds, then user can adjust the
intensity of standby light by pr or – button, total 3
intensity can be selected.
Long press button for 20 seconds to make heating
elements fail to work, other operations can be operated
normally. Long press 20 s again to deactivate.
This marking indicates that this product
should not be disposed with other
household wastes throughout the EU. To
prevent possible harm to the
environment or human health from
uncontrolled waste disposal, recycle it
responsibly to promote the sustainable
reuse of material resources. To return
your used device, please use the return
Recycling
www.electrolux.com
10
°C
P
This product has automatic
shut down function if
temperature decreased by 5
dgrees in 10 minutes
Problem
Probable Cause
Solution
Short circuit or open circuit
may happened on NTC of
product
Error code E0
will show on
display
Error code E1
or E2 show on
display
User need to restart the product by
pressing standby power button.
User need to send product to
designated
After-sales Service
Agency
to repair, NTC need to be
re-insert and trun on the product
again.
6.
TROUBLE SHOOTING
and collection systems or contact the
retailer where the product was
purchased. They can take this product
for environmental safe recycling.
Factory reset
Long press button for 20 seconds to make the product
back to factory setting.
Odor flavour
Generated by heating
element when first time use.
This is normal and will be reduced
gradually during use.