3.2
Control knobs
Symbol
Description
no gas supply /
off position
ignition position /
maximum gas
supply
Symbol
Description
minimum gas
supply
4.
DAILY USE
WARNING!
Refer to the Safety chapters.
4.1
Ignition of the burner
WARNING!
Be very careful when you use
open fire in kitchen environment.
Manufacturer decline any respon-
sibility in case misuse of the flame
Always light the burner before you
put cookware.
To light the burner:
1.
Turn the control knob counterclock-
wise to the maximum position (
) and push it down.
2.
Keep the control knob pushed for ap-
proximately 5 seconds; this will let
thermocouple to warm up. If not, the
gas supply will be interrupted.
3.
Adjust the flame after it is regular.
If after some tries the burner does
not light, check if the crown and
its cap are in correct positions.
A
B
C
A)
Burner cap and crown
B)
Thermocouple
C)
Ignition candle
WARNING!
Do not keep the control knob
pushed for more than 15 sec-
onds.
If the burner does not light after
15 seconds, release the control
knob, turn it into off position and
try to light the burner again after
minimum 1 minute.
In the absence of electricity you
can ignite the burner without elec-
trical device; in this case approach
the burner with a flame, push the
relevant knob down and turn it
counter-clockwise to maximum
gas release position.