• from liquid gas to natural gas G20
20 mbar, undo the bypass screw
approximately 1/4 of a turn.
WARNING!
Make sure the flame does not
go out when you quickly turn
the knob from the maximum
position to the minimum
position.
8.5
Electrical connection
• Make sure that the rated voltage and
type of power on the rating plate agree
with the voltage and the power of the
local power supply.
• This appliance is supplied with a mains
cable and a plug.
• Always use a correctly installed
shockproof socket.
• Make sure that there is an access to
the mains plug after the installation.
• Do not pull the mains cable to
disconnect the appliance. Always pull
the mains plug.
• There is a risk of fire when the
appliance is in connection with an
extension cable, an adapter or a
multiple connection. Make sure that the
ground connection agrees with the
standards and regulations.
• Do not let the power cable to heat up
to a temperature higher than 90° C.
Make sure that you connect
the blue neutral cable to the
terminal with a letter "N" on it.
Connect the brown (or black)
phase cable to the terminal
which has a letter "L". Keep
the phase cable connected at
all times.
8.6
Connection cable
To replace the connection cable use only
the special cable or its equivalent. The
cable type is: H05V2V2-F T90.
Make sure that the cable section is
applicable to the voltage and the working
temperature. The yellow / green earth wire
must be approximately 2 cm longer than
the brown (or black) phase wire.
8.7
Building In
min. 55 mm
min. 650 mm
550 mm
min. 100 mm
30 mm
470 mm
A
B
A)
supplied seal
B)
supplied brackets
CAUTION!
Install the appliance only on a
worktop with flat surface.
8.8
Possibilities for insertion
The panel installed below the hob must be
easy to remove and let an easy access in
case a technical assistance intervention is
necessary.
ENGLISH
13