To replace the connection cable
use only H05V2V2-F T90 or
equivalent type. Make sure that
the cable section is applicable to
the voltage load and the working
temperature. The yellow/green
earth wire (B) must be approxi-
mately 2 cm longer than the live
and neutral wire (A).
A
B
WARNING!
A cut off plug inserted into a 13
amp socket is a serious safety
(shock) hazard. Ensure that the
cut off plug is disposed of safely.
The replacement of electric cable
must be carried out exclusively by
the service force centre or by per-
sonnel with similar competencies,
in accordance with the current
regulations.
8.6
Building In
min. 600 mm
min. 55 mm
min. 650 mm
560 mm
480 mm
min. 450 mm
30 mm
10 mm
3 mm
11 mm
11 mm
A
A
B
A)
supplied seal
B)
supplied brackets
CAUTION!
Install the appliance only on a
worktop with flat surface.
8.7
Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must
be easy to remove and let an easy access
in case a technical assistance intervention
is necessary.
min 20 mm
(max 150 mm)
30 mm
60 mm
B
A
A)
Removable panel
B)
Space for connections
14 www.electrolux.com