A
B
min. 20
15
20
A
4.
Use at least 2 screws to fix the oven
on both sides (Detail A).
WARNING!
When installing next to a wood-fu-
elled boiler, a heatproof and heat-
insulating plate must be mounted
at the height of the appliance and
at least 30 cm deep.
ELECTRICAL CONNECTION
Use a power cable of H05VV-F or higher.
Connect the appliance to a socket supply
line. If there is no socket supply line, the
electrical installation must have an isolation
device which lets you disconnect the appli-
ance from the power supply. The isolation
device must have a contact opening width
of minimum 3 mm (in reference to NIN SEV
1000). The customer must have a socket
for the electrical connection that is accessi-
ble and outside the coordination room. The
length of the connection cable must be ap-
proximately 120 cm with lines connected
directly to the power supply.
L2 L3
400V
L1
PE
400V 3~
L2
400V
L1
PE
400V 2~
1
2
3
4
5
1
2
3
4
5
Only a qualified person can con-
nect the appliance to the electricity
supply.
1.
Do the electrical connections as in the
connection illustration.
Connection diagram 400V
Phase definitions: L1, L2, L3 (or R, S,
T).
2.
Secure the cable grip.
WARNING!
If service is required always discon-
nect the appliance from the power
supply.
ENGLISH
27