Basic Information
1-7
Microwave Measurement Procedure (Canada)
After adjustment of the door switches are completed individually or collectively, switch test and microwave leakage
test must be performed with survey instrument and test result must be confirmed to meet the requirement of the
performance standard for microwave ovens as under mentioned.
A. Requirements:
Every microwave oven shall function in such a manner that when the oven is fully assembled and operating with
its service controls and user controls adjusted to yield the maximum output, the leakage radiation, at all points at
least 5 cm. from the external surface of the oven, does not exceed:
1) 1.0 mW/cm2 with the test load of 275 ± 15 ml of water at an initial temperature 20 ±5°C.
2) 5.0 mW/cm2 when the outer enclosure is removed with a test load of 275 ± 15 ml of water at an initial
temperature
20±5°C.
3)
5.0
mW/cm2 without a test load.
B. Preparation for testing:
Before beginning the actual measurement of leakage, proceed as follows:
1) Make sure that the actual instrument is operating normally as specified in its instruction booklet.
Survey instruments that comply with the requirement for instrumentation as prescribed by CSA and NHW
performance standard for microwave ovens must be used for testing recommended instruments are, NARDA
8100 and NARDA 8200.
2) Place the oven tray in the oven cavity.
3) Place the load of 275±15 ml (9.8 oz) of tap water initially at 20°±5C (68±9°F) in the center of oven cavity.
The water container shall be a low form of a 600 ml (20 oz) beaker with an inside diameter of approx. 8.5 cm
(3-1/2 in.) and made of an electrically nonconductive material such as glass or plastic. The placing of
this standard load in the oven is important not only to protect the oven, but also to insure that any leakage is
measured
accurately.
4) Set the cooking control on Full Power Cooking Mode.
5) Close the door and select a cook cycle of several minutes. If the water begins to boil before the survey is
completed, replace it with 275 ml of cool water.
C. Leakage test with enclosure installed:
1) Grasp probe of survey instrument and hold it perpendicular to gap between door and the body of the oven.
2) Move the probe slowly, not faster than 2.5 cm/sec. along the gap, watching for maximum indication on meter.
3) Check for leakage at the door screen, sheet metal seams and other accessible positions where the continuity
of the metal has been breached (eg., around the switches, indicator, and vents). While testing for leakage
around door, pull door away from the front of the oven as far as is permitted by the closed latch assembly.
4) Measure carefully at the point of highest leakage and make sure that the highest leakage is no greater
than
4
mW/cm2, and that the primary interlock switch and secondary interlock switch do turn the oven
OFF before any door movement.
D. Leakage test without enclosure:
1) Remove the enclosure (cabinet).
2) Grasp the probe of the survey instrument and hold it perpendicular to all mechanical and electric parts of the
oven that is accessible to the user of the oven including, but not limited to, the waveguide, cavity seams,
magnetron gap between the door and the body of the oven.
3) Move probe slowly, not faster than 2.5 cm/sec. along the gap, watching for the maximum indication on meter.
4) Measure carefully at the point of highest leakage and make sure that the highest leakage is under 5 mW/cm2.
CAUTION: Special attention should be given to avoid electrical shock because HIGH VOLTAGE is generated
during this test.
E. No Load test
1) Operate the oven without a load and measure the leakage by the same method as the above test procedure
“ Leakage test with enclosure installed”
2) Make sure that the highest leakage should not exceed 5 mW/cm2.
NOTE:
After servicing, record data on service invoice and microwave leakage report.
Summary of Contents for EI24MO45IBA
Page 2: ......
Page 18: ...Operation 2 6 Notes ...
Page 38: ...Component Teardown and Testing 4 10 Notes ...
Page 39: ...Wiring Diagrams 5 1 Wiring Diagram ...
Page 40: ...Wiring Diagrams 5 2 Oven Wiring Schematic Off Condition ...
Page 41: ...Parts List 6 1 Key Unit And Door Assembly ...
Page 42: ...Parts List 6 2 ...