Component Teardown
4-4
Oven Lamp and Lamp Socket
Removal
1. Disconnect oven from power supply and remove
outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Pull the wire leads from the oven lamp socket.
5. Remove support bracket and the magnetron duct.
6. Unscrew the oven lamp from the lamp socket.
7. Remove socket from magnetron duct.
8. Now, the oven lamp and socket are free.
To discharge the high voltage capacitor, wait for 60
seconds and then short-circuit the connection of
the high-voltage capacitor (that is the connecting
lead of the high-voltage rectifier) against the
chassis with the use of an insulated screwdriver.
Oven Lamp
Socket
Terminals
Magnetron Duct
Positive Lock®, Connector
Terminal
Push
Pull down
1
2
Lever
Positive lock
connector
Figure 4-2. Oven Lamp Socket
Figure 4-3. Positive Lock
®
Connector
Positive Lock
®
Connector (No-Case
Type) Removal
1. Disconnect oven from power supply and remove
outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Push the lever of positive lock
®
connector.
5. Pull down on the positive lock
®
connector.
To discharge the high voltage capacitor, wait for 60
seconds and then short-circuit the connection of
the high-voltage capacitor (that is the connecting
lead of the high-voltage rectifier) against the
chassis with the use of an insulated screwdriver.
When connecting the positive lock
®
connectors to
the terminals, connect the positive lock
®
so that
the lever faces you.