background image

30" Electric Freestanding Range Specifications

Product Weight – 240 Lbs.

Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz,
fused on both sides of line with ground.

Connected Load (kW Rating) @ 240 / 208 Volts = 15.0 / 11.5 kW

Amps @ 240 / 208 Volts = 38.3 / 32.5 Amps

Recommended Circuit Breaker – 50 Amps

Always consult local and /or national electric codes.

Overhead cabinetry should not exceed a 13" maximum depth.

Allow 30" minimum clearance between rangetop and bottom of
unprotected wood or metal overhead cabinetry.

Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum width
of appliance.

Allow 24" minimum clearance when bottom of wood or metal overhead
cabinet is protected by not less than 1/8" flame-retardant millboard
covered with not less than No. 28 MGS sheet steel, 0.015" stainless
steel, 0.024" aluminum or 0.020" copper.

Allow 1" minimum clearance from edge of rangetop to nearest
combustible wall on either side of unit.

To reduce risk of fire when using overhead cabinetry, install range hood
that projects horizontally a recommended minimum of 5" beyond bottom
of cabinets.

Note: For planning purposes only. Refer to Product Installation Guide 

on the web at electroluxappliances.com for detailed instructions.

Optional Accessories

Grill / Griddle – (318251611).

Electric Freestanding Ranges

EI30EF55G S, EI30EF55G W, EI30EF55G B

High standards of quality at Electrolux Major Appliances mean we are 

constantly working to improve our products. We reserve the right to change 

specifications or discontinue models without notice.

USA

250 Bobby Jones Expressway 

Augusta, GA 30907 

1-877-4electrolux (1-877-435-3287) 

electroluxappliances.com

CANADA

5855 Terry Fox Way 

Mississauga, ON L5V 3E4 

1-800-265-8352 

electroluxappliances.ca

EI30EF55G  01/08

© 2008 Electrolux Major Appliances, NA

Printed in the U.S.A.

28

5

/

8

"

26

3

/

8

"

Side

Overall depth

including oven

door in 90

°

open

position – 48

13

/

16

"

Front

11

5

/

8

"

35

7

/

8

"

Adjustable

to

36

1

/

8

"

29

7

/

8

"

47

1

/

2

"

Note: All dimensions for

electrical outlet location

are maximum

30" min.

13"

max.

 25"

24"

 1" min.
to nearest
combustible
wall (either
side of unit)
above 36"
height

30

1

/

8

"

6"

2

5

/

8

"

Area allows for flush

installation of rear

wall electrical outlet

CL

22"

11"

18" min.

36"

stand.

34"

min.

Power supply

location

(right bottom

rear)

Reviews: