1.1.0 5.2007
11/40
Refreshment Center
Main components
Compressor
Function:
Works in refrigerant circuit pushing the gas through the capillary. In
this appliance, the compressor works also in reverse cycle.
Technical data:
Ref.: GD30MB-D
Power: 1/12 Hp
220V-50Hz
Gas type: R134a
Resistance: AC 25
Ω
, CP 25
Ω
, AP 50
Ω
A
C
P
Pump
Function:
In hydraulic circuit, it pushes the water through the heat exchanger
and into the carbonizing device.
Technical data:
Ref.: Acquatec 5873 2K01 V704
Flow: 1,3 GPM
Bypass: 120 PSI
Diode measure type: 980 mV
Inar Lock connector