14.10 Hob injectors
replacement
Replace the injectors when you change
the gas type.
1. Remove the pan supports.
2. Remove the caps and crowns of the
burner.
3. Remove the injectors with a socket
spanner 7.
4. Replace injectors with the ones
necessary for the type of gas you
use.
5. Replace the rating plate (it is near the
gas supply pipe) with the one for the
new type of gas supply.
You can find this plate in
the bag supplied with the
appliance.
If the supply gas pressure is not constant
or it is different from the necessary
pressure, install an applicable pressure
adjuster on the gas supply pipe.
14.11 Adjusting the minimum
gas level on the hob burner
1. Disconnect the appliance from the
electricity.
2. Remove the knob for the hob. If there
is no access to the bypass screw
dismount the control panel before
adjustment start.
3. With a thin and flat screwdriver adjust
the bypass screw A.
The model determines the position of
the bypass screw A.
A
A
Changing from natural gas to
liquid gas
1. Fully tighten the bypass screw.
2. Put the knob back.
Changing from liquid gas to
natural gas
1. Unscrew approximately one turn the
bypass screw position A.
2. Put the knob for the hob back.
3. Connect the appliance to the
electricity.
WARNING!
Put the mains plug into
the mains socket only if
all parts are back into
their initial position.
There is a risk of injury.
4. Light the burner.
Refer to "Hob - Daily use" chapter.
5. Turn the knob for the hob to the
minimum position.
6. Remove the knob for the hob again.
7. Screw on slowly the bypass screw till
the flame becomes minimum and
stable.
8. Put the knob for the hob back on.
14.12 Oven injector
replacement
1. Remove the bottom plate of the oven
cavity to get access to the oven
burner .
ENGLISH
27