12.1 Building In
594
16
573
21
548
min. 550
20
600
min. 560
558
589
114
594
3
5
558
21
548
min. 550
20
589
594
114
16
573
590
min. 560
594
3
5
12.2 Securing the appliance to
the cabinet
A
B
12.3 Electrical installation
The manufacturer is not
responsible if you do not
follow the safety precautions
from the Safety chapters.
This appliance is supplied with a main
plug and a main cable.
12.4 Cable
Cable types applicable for installation or
replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05
VV-F, H05 V2V2-F (T90), H05 BB-F
For the section of the cable refer to the
total power on the rating plate. You can
also refer to the table:
Total power (W)
Section of the ca‐
ble (mm²)
maximum 1380
3 x 0.75
maximum 2300
3 x 1
maximum 3680
3 x 1.5
The earth cord (green / yellow cable)
must be 2 cm longer than phase and
neutral cables (blue and brown cables).
ENGLISH
25