IMPORTANT

may result in loss of warranty as per Chap-

ter 9 in this manual.

WARNING:

This product is intended for domestic use and similar applications, such as:

- Farm houses and by clients in hotels, motels and other residential environments;

- Half-boarding environments;

- Buffet and similar applications not intended for retail.

Model

EPWC1MEUKG

Width (mm)

250

Height (mm)

358

Depth (mm)

314

Mass (Kg)

5.7

Voltage (V)

220-240

Frequency (Hz)

50/60

Maximum output (W)

73

Water pressure (kPa)

39 to 392.26 kPa

3 - 38

0

C

Protection class

IPX0 (indoor use)

Color

Silver

Natural water tank volume (ml)

900

Cooling capacity (l/h)

0.2

Power consumption (kW/h/month)

7.0

Cold water tank volume (ml)

800

Filtering 

System

Particle retention

Class A

Free chlorine reduction

Approved
Approved

Filtering element life

3000 liters or 12  months

UV lamp life

3000 liters or 12 months

* Values according to BATS NBR 16236:2013.

This product is intended to be used in drinkable 

water that complies with local legislation.
If  necessary,  use  a  transformer  of  at  least 

1000VA.   

 

Design working temperature for inlet water

Summary of Contents for EPWC1MEUKG

Page 1: ...EPWC1MEUKG INSTRUCTION MANUAL WATER PURIFIER ...

Page 2: ...se by persons including children with reduced physical sen sory or mental capabilities or lack of experi ence and knowledge unless they have been given supervision or instruction concerning the use of the product by a person responsible for their safety Never leave lighted candles or incense on the Child Safety Avoid accidents After unpacking the appliance keep the packaging materials out of the r...

Page 3: ...l water Do not use it to freeze any other type of beverage as it may cause damages to the product resulting in loss of warranty Disconnect the product from when it is left unused for a long time This appliance was developed for domestic use and designed to be used with drink able water that complies with the current legislation 4 5 4 UV lamp 5 Fixing screws and bushings 2 sets of 5 mm QUANTITY NAT...

Page 4: ...iance An installation fee may be charged for this service Such installation does not include site prepara tion service or the materials for the installation e g masonry electrical network power outlet circuit breaker grounding hydraulic network as these would be the responsibility of the consumer Installation site Do not install the appliance in a place where it is exposed to direct sunlight or ne...

Page 5: ... indicat ed in the Allowable Voltage Variation table ask the power utility company to adjust the voltage levels or install a voltage regulator stabilizer with a power of 1000VA or less Allowable Voltage Variation Voltage V Minimum V Maximum V 127 116 133 220 240 201 255 hooks IMPORTANT If you wish to use water from artesian or homemade wells it is important to have a report that proves the indicat...

Page 6: ...igure 3 4 Fit the water inlet hose into the connection and push it all the way to the end Figure 3 Filter Installation 1 Press the appliance cover to open it Figure 4 2 Open the appliance cover Figure 5 3 4 to the product and screw in the direction indi cated until it is aligned with the arrow to lock it Figure 6 5 Open the water supply so that the product 6 Press and hold the RESET FILTER button ...

Page 7: ...igure 10 Figure 11 UV Lamp Installation 1 Unplug the product from the power outlet and remove the lamp from the EPS housing 2 Position the lamp carefully over the housing without releasing it Figure 8 3 Connect the UV lamp to its power cable con nector Figure 9 4 Snap the connector into the housing and at tach the cable to the clip Figure 10 5 Plug the product into the power outlet and press the R...

Page 8: ...Indicator when one of these two components needs to be replaced after 12 months of use or after approximately 3000 litres of water consumed tor is on refer to the next chapter for cleaning and maintenance of the product 6 Cleaning and Maintenance Under normal usage conditions installation and lights up after 3000 litres or 12 months from the Filter Replacement lights up after 3000 liters or 12 mon...

Page 9: ...p cover remove the plastic cov er that protects the hole and pour a teaspoon 5 ml of colorless alcohol vinegar Open the water supply and wait for approxi Pour another teaspoon 5 ml of alcohol vinegar After 10 minutes empty the tank using the drainage port located at the back of the product and discard the water it by removing at least 5 liters from each tank ice cold and natural before using it ag...

Page 10: ... on Pages 8 and 9 The appliance indicating the Water leakage Loose pipe connection Make sure that the appliance s water pipe connections have been properly secured Damaged connectors or hose Please contact the Electrolux Authorized Service No water comes out Tap or water supply closed Open the tap or water supply Water pressure is too low Make sure the water pressure is above 4 mca 39 kPa Check th...

Page 11: ... Maximum output W 73 Water pressure kPa 39 to 392 26 kPa 3 380 C Protection class IPX0 indoor use Color Silver Natural water tank volume ml 900 Cooling capacity l h 0 2 Power consumption kW h month 7 0 Cold water tank volume ml 800 Filtering System Particle retention Class A Free chlorine reduction Approved Approved Filtering element life 3000 liters or 12 months UV lamp life 3000 liters or 12 mon...

Page 12: ...12 Notes ...

Page 13: ...13 Notes ...

Page 14: ...14 ...

Page 15: ...15 ...

Page 16: ...https www electroluxarabia com support contact us Electrolux Appliances S P A Corso Lino Zanussi 24 33080 Porcia PN Italy ...