5
Putting Ergobox back
Make sure Ergobox and the filters are dry.
Make sure the motor filter is in place. (See
also Replacement of filter(s).) Make sure the
washable HEPA filter is in place. (See also
Replacement of filter(s).)
28
Fix the front and rear parts together
with the 3 hooks.
Close the catch by fixing the metal fastening.
29
Put Ergobox back in the cleaner.
Replacement of the filter(s)
The more often the better for the efficiency
of the cleaner. Never use the vacuum cleaner
without filter(s).
A Motor-filter (Ref. No. EF 54)
23
Grasp Ergobox and lift it out as
shown in the illustration.
30
Pull the filter holder upwards until
it comes away from the groove.
Carefully pull the old, dirty filter(s) out
of the filter holder and replace with a
new filter(s).
31
Reinstall the filter holder containing
the new filter(s).
B Washable HEPA filter (Ref. No. EF
75B). Follow steps 22, 23, 24.
27
Turn the washable HEPA filter anti-
clockwise and pull it away. To put
a clean one back, push and turn it
clockwise.
Cleaning the hose and nozzle
The vacuum cleaner stops automatically
if the nozzle, tube, hose or filters become
blocked. In such cases, disconnect from
mains and allow to cool for 20-30 min-
utes. Clear blockage and/or replace filters
and restart.
Tubes and hoses
34
Use a cleaning strip or similar to clear
the tubes and hose.
Hose handle could be dismantled
from hose if cleaning is needed.
35
It may also be possible to remove the
obstruction in the hose by squeez-
ing it. However, be careful in case
the obstruction is caused by glass or
needles caught inside the hose.
Note: The warranty does not cover any dam-
age to the hose caused by cleaning it.
Cleaning the floor nozzle
36*
Press each wheel-hub and draw away
the wheels. Use the crevice nozzle to
clean the wheel axles. Remove dust-
balls, hair or other objects that may
be entangled. Replace the wheels by
pressing them onto the axles.
37*
Larger objects can be accessed by
removing the connection hose from
the nozzle (press the small catches
located on each side and simultane-
ously draw the connection tube out-
wards in an upright position).
38*
Remove the object(s) and replace the
connection hose.
39
To avoid loss of suction power, fre-
quently clean the carpet/hard floor
nozzle. The easiest way to clean it is
by using the hose handle.
Cleaning the turbo nozzle*
40
Disconnect the nozzle from the
vacuum cleaner tube and remove
entangled threads, etc. by snipping
them away with scissors. Use the
hose handle to clean the nozzle.
Troubleshooting
The vacuum cleaner does not start
• Check that the cable is connected to
the mains.
• Check that the plug and cable are not
damaged.
• Check for a blown fuse.
The vacuum cleaner stops
• Check if Ergobox is full. If so, empty it
and clean both the box and the filter
before putting it back in the cleaner.
• Is the nozzle, tube or hose blocked?
• Are the filters blocked?
Water has entered the vacuum cleaner
It will be necessary to replace the motor
at an authorised Electrolux service cen-
tre. Damage to the motor caused by the
penetration of water is not covered by the
warranty.
Consumer information
Electrolux decline all responsibility for all
damages arising from any improper use
of the appliance or in cases of tampering
with the appliance.
This product is designed with the environ-
ment in mind. All plastic parts are marked
for recycling purposes. For details see our
web site: www.electrolux.com
If you have any comments on the cleaner
or the Instructions for Use booklet please
e-mail us at: floorcare@electrolux.com
If you can´t find accessories to your Electrolux
vacuum cleaner, please visit our website at
www.electrolux.co.uk or call 08706 055 055.
*Certain models only. **Execution depending on model.
ergobox_040819.indd 5
ergobox_040819.indd 5
8/20/04 5:04:37 PM
8/20/04 5:04:37 PM