background image

3

ENGLISH

1.  SAFETY INFORMATION

For your safety and correct operation of the appliance, 
read this manual carefully before installation and use. 

Always keep these instructions with the appliance even if 
you move or sell it. Users must fully know the operation 
and safety features of the appliance.

The wire connection has to be done by specialized 

technician.

• The manufacturer will not be held liable for any damages 

resulting from incorrect or improper installation.

• The minimum safety distance between the cooker top and 

the extractor hood is 650 mm (some models can be installed 
at a lower height, please refer to the paragraphs on working 
dimensions and installation).

• If the instructions for installation for the gas hob specify a 

greater distance, this must be respected. 

• Check that the mains voltage corresponds to that indicated 

on the rating plate fixed to the inside of the hood.

• 

Means for disconnection must be incorporated in the fixed 

wiring in accordance with the wiring rules.

• For Class I appliances, check that the domestic power sup-

ply guarantees adequate earthing.

• 

Connect the extractor to the exhaust flue through a pipe of 

minimum diameter 120 mm. The route of the flue must be 

as short as possible.

• Regulations concerning the discharge of air have to be 

fulfilled.

• Do not connect the extractor hood to exhaust ducts carrying 

combustion fumes (boilers, fireplaces, etc.).

• If the extractor is used in conjunction with non-electrical ap-

pliances (e.g. gas burning appliances), a sufficient degree of 

aeration must be guaranteed in the room in order to prevent 

the backflow of exhaust gas. When the cooker hood is used 

in conjunction with appliances supplied with energy other 
than electric, the negative pressure in the room must not 
exceed 0,04 mbar to prevent fumes being drawn back into 
the room by the cooker hood.

• 

The air must not be discharged into a flue that is used for 

Summary of Contents for ERI635DSE

Page 1: ...Cooker hood Dunstabzugshaube Hotte de cuisine Cappa User manual Gebrauchsanleitung Manuel d utilisation Libretto di uso 3 7 13 19 EN DE FR IT ERI635DSE ERI935DSE ...

Page 2: ...come to Electrolux Visit our website for Get usage advice brochures trouble shooter service information www electrolux com Register your product for better service www registerelectrolux com Buy Accessories Consumables and Original spare parts for your appliance www electrolux com shop CUSTOMER CARE AND SERVICE Always use original spare parts When contacting our Authorised Service Centre ensure th...

Page 3: ...ted on the rating plate fixed to the inside of the hood Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules For Class I appliances check that the domestic power sup ply guarantees adequate earthing Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm The route of the flue must be as short as possible Regulations concer...

Page 4: ...n be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concern ing use of the appliance in a safe way and understand the hazardsinvolved Childrenshallnotplaywiththeappliance Cleaning and user maintenance shall not be made by chil dren without supervisio...

Page 5: ...ollection point for the recycling of electrical and electronic equip ment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could other wise be caused by inappropriate waste handling of this product For more detailed information about recycling of this product please contact your local city office your...

Page 6: ...to avoid a hazard Ensure that the plug is accessible after installation ACCESSORIES When using flexible duct always install duct with the wire helix pulled taut to minimise pressure loss Try to keep exhaust duct short and straight Keep bends in the exhaust duct to a minimum Do not restrict exhaust duct Reducing the size of the exhaust duct will reduce the airflow of the rangehood Please read instr...

Page 7: ...CAREANDCLEANING The Activated charcoal filter is not washable and cannot be re generated and must be replaced approximately every 4 months of operation or more frequently for particularly heavy usage W W W W TheGreasefiltersmustbecleaned every 2 months of operation or more frequently for particularly heavy usage and can be washed in a dishwasher Z Z Z Clean the hood using a damp cloth and a neutra...

Page 8: ...d is timed to run for 6 minutes At the end of this time the system returns automatically to the speed that was set before If it is activated with the motor turned off the hood will switch to OFF at the end of the time Fixed S1 Signals the Metal Grease Filter saturation alarm indicating that it is necessary to wash the filters The alarm is triggered after the Hood has been in operation for 100 work...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...electrolux com shop 991 0627 944_01 201027 D00007117_01 ...

Reviews: