background image

EN

  AIR CONDITIONER

USER MANUAL 

2

ESM09CRR-B3

 

ESM12CRR-B3

 

ESM18CRR-B3

ESV09CRS-B2

 

ESV12CRS-B2

 

ESV09CRR-C6

 

ESV09CRR-C7

Summary of Contents for ESM09CRR-B3

Page 1: ...EN AIR CONDITIONER USER MANUAL 2 ESM09CRR B3 ESM12CRR B3 ESM18CRR B3 ESV09CRS B2 ESV12CRS B2 ESV09CRR C6 ESV09CRR C7 ...

Page 2: ...ts for your appliance www electrolux com shop CUSTOMER CARE AND SERVICE We recommend the use of original spare parts When contacting Service ensure that you have the following data available The information can be found on the rating plate Model PNC Serial Number Warning Caution Safety information General information and tips Environmental information Subject to change without notice 2 www electro...

Page 3: ...ordance with the national wiring standards and the electricity suppliers service rules by authorised personnel only If the unit is to be moved to another location or disposed of only a suitably qualified person is permitted to undertake such work If you notice an unusal situation such as a burning smell please switch off the power to the air conditioner and contact an Electrolux service agent If t...

Page 4: ...Do not step on the top of the outdoor unit or place heavy things on it It may cause damage or injury Do not attempt to repair the air conditioner by yourself Incorrect repairs may cause electric shock or re Please contact your local authorised service centre Do not insert your hands or objects into the air inlet or outlet It may cause injury Do not expose animals or plants directly to the airflow D...

Page 5: ...ol button 8 Ion generator if applicable 9 Remote controller 10 Remote controller Holder some units 11 Refrigerant pipe 12 Drain hose 13 Power cable some units 14 Mounting plate 15 Connecting cable 16 Power cable some units All the pictures in this manual are for explanation purposes only The actual shape of the indoor unit you purchased may be slight different on front panel and display window The...

Page 6: ...ote controller to direct sunlight or heat If the infrared signal receiver on the indoor unit is exposed to direct sunlight the air conditioner may not function properly Use curtains to prevent the receiver being exposed to sunlight If other electrical appliances react to the remote controller either move these appliances or consult your local dealer For some models we do not have the display in th...

Page 7: ...rom the remote controller exposing the battery compartment and insert two new alkaline dry batteries 2x AAA 1 5 Volt Make sure that the polarity of or is installed correctly Slide the battery compartment cover back on When changing batteries do not use old or varied ones otherwise it may cause problems with the remote controller If the remote controller is not used for a long time remove the batte...

Page 8: ...art vertical louver movement or set the desired left right air flow direction For the models without Swing Left Right function there is no feedback received by the indoor unit when you press the button 4 TURBO BUTTON In COOL or HEAT mode press the button to enable or disable the turbo function If the turbo function is enabled the unit will operate at turbo speed to cool or heat rapidly so that the...

Page 9: ...s to use while sleeping 14 HEALTH BUTTON Press the button to enable or disable Health function Default setting OFF 15 LIGHT BUTTON Press the button to switch the display of the indoor unit on or off Default setting ON 16 MODE DISPLAYS Displays the current selected mode Including Auto Cool Dry Heat and Fan For Cooling only models there is no HEAT mode available 17 FAN SPEED DISPLAYS Displays the se...

Page 10: ...perature can be set in 1ºC increments Keep the button pressed for two seconds to accelerate the process 4 Press the FAN SPEED button D to select the fan speed 5 Press the ON OFF button A to turn the air conditioner off In the Auto mode the air conditioner can logically choose the mode of Cool Fan and Heat by sensing the difference between the actual ambient room temperature and the set temperature...

Page 11: ... For the models without Swing Left Right function there is no feedback received by the indoor unit when you press the button Timer Operation A B Press the Timer button A can set the auto on time and the auto off time of the unit To set the Timer on time 1 When the remote controller is at off state press the Timer button the Timer on signal and time will show on the display 2 Press the button to se...

Page 12: ...ller is at off state press the Timer button the Timer on signal and time will show on the display 2 Press the button until 6 0h display on the remote controller 3 Press the Timer button again to active the Timer on function TIMER OFF Example It is 6 00 PM and you want the air conditioner to turn off after 10 hours 1 When the remote controller is at on state press the Timer button the Timer off sig...

Page 13: ... information at its location to the indoor unit The air conditioner will quit I Feel operation if no temperature information is received from the remote controller 4 I Clean function Press the I clean button to activate the I Clean feature when this function is activated firstly the indoor unit operates in cooling mode with low fan speed for serveral minutes After that the unit turns to heating op...

Page 14: ...models is energized and will help to remove pollen and impurities from the air and I feel function will be activated at the same time room temperature will automatically change to 26ºC I feel function can be canceled by pressing I Feel button also room temperature setting be adjusted by pressing button This function is recommended when the indoor air quality is in bad condition 9 Wireless function...

Page 15: ...e unit is in operation Use the remote controller to adjust the air flow direction The horizontal louver can swing up and down automatically To set the horizontal air flow direction Left Right Perform this function while the unit is in operation Use the remote controller to adjust the air flow direction The vertical louver can swing left and right automatically For models without 3D Swing function ...

Page 16: ...is operational continue pressing the manual control button until the unit is off This switch is used for testing purposes only You had better not choose it To restore the remote controller operation use the remote controller directly Manual control button Operating temperature ranges Model climate Type Ambient temperature Cooling Ambient temperature Heating T1 18 C 43 C 7 C 43 C Important 1 Optimu...

Page 17: ...he unit with a soft dry cloth only If the unit is very dirty wipe it with a cloth soaked in warm water 10 3 Cleaning the Filters A clogged air filter reduces the cooling efficiency of this unit Please clean the filter once every 2 weeks 1 Lift the indoor unit front panel up to an angle until it stops with a full support from the bracket 2 Hold the dust flter handle and lift it up slightly to take ...

Page 18: ...on If you plan to idle the unit for a long time perform the following 1 Clean the indoor unit and filters 2 Operate the fan for about half a day to dry the inside of the unit 3 Stop the air conditioner and disconnect power 4 Remove the batteries from the remote controller The outdoor unit requires periodic maintenance and cleaning Do not attempt to do this yourself Contact your dealer or service p...

Page 19: ...starts in HEAT mode operation after defrosting 5 Abnormal noise of the air conditioner You may hear a low hissing sound when the compressor is running or has just stopped running It is the sound of the refrigerant flowing or coming to a stop You can also hear a low squeak sound when the compressor is running or has just stopped running This is caused by heat expansion and cold contraction of the p...

Page 20: ...ioner decreases accordingly At the same time heat loading of the air conditioner increases due to larger difference between indoor and outdoor temperature If a comfortable temperature can t be achieved by the air conditioner we suggest you use a supplementary heating device 11 Auto restart function Power failure during operation will stop the unit completely For the unit without Auto restart featu...

Page 21: ...wer to be restored Unit may have become Unplugged Check that plug is securely in wall receptacle Fuse may have blown Replace the fuse Battery in Remote controller may have been exhausted Replace the battery The time you have set with timer is incorrect Wait or cancel timer setting Unit not cooling or heating Cooling heating models only room very well while air flowing out from the air conditioner ...

Page 22: ...www electrolux com shop 91030a ...

Reviews: