Page 1: ...818 34 32 01 5 INSTRUCTION BOOK GEBRAUCHSANWEISUNG ISTRUZIONI D USO NOTICE D UTILISATION EUC2200 FR DE F r e e z e r G e f r i e r G o n g e l a t o r e Co n g é l a t e u r GB IT ...

Page 2: ...vy The edges and projecting parts of the cabinet may be sharp Be careful when moving the cabinet and always use gloves Child Safety Pay attention so that small children do not gain access to the operating controls or the inside of the cabinet Scrapping old cabinets When discarding the cabinet hand it over to a recycling station For more information call your local city office or your dealer Conten...

Page 3: ...FAST FREEZE button Used to switch the Fast Freeze feature on and off E Yellow indicator lamp Lights when Fast Freeze is operating F Alarm shut off button Used to turn the audible alarm off G Red warning lamp Flashes when one of the alarms in the cabinet has been triggered Before use GB Position and clean the cabinet as explained in the section Installation Before inserting the power plug into the ...

Page 4: ...s with a lot of food or if the cabinet is run entirely or partially without accessories the thermometer display can be adjusted for these conditions When adjusting the thermometer display the cabinet should be working and freezing should not be active Press the shut down button for the Setting the temperature and the button simultaneously and hold them down for about 5 seconds As confirmation the ...

Page 5: ...rking Temperature memory The temperature memory shows when an alarm has been triggered in the cabinet The temperature memory operates as follows When the temperature inside the freezer again falls below 11 C the audible alarm stops The temperature display and the red warning lamp will flash to indicate than an alarm was triggered When the alarm shut off button is pressed the display then displays ...

Page 6: ...en food The heat from the unfrozen food may cause the frozen food to thaw on the surface Once frozen re arrange the products and put them as close as possible to each other The food will then stay cold longer in the event of a power failure Do not freeze too much food at the same time The freezing capacity of the unit is indicated in the specifications section Suitable storage periods Food purchas...

Page 7: ...d provisions the accumulator moves to the tray space nearest to the lower freezing shelf When defrosting Place the cold accumulator on top of the frozen food to keep it cold Hints and Tips GB Saving energy Pay careful attention to where the cabinet is placed See the section Installation When installed correctly the cabinet will consume less energy Try to avoid keeping the door open for long period...

Page 8: ...antling and subsequent recycling Maintenance and Cleaning GB Removing the ventilation grille The ventilation grille can be removed e g to wash the grille Make sure the door is open when removing the ventilation grille Unsnap the upper edge of the grille by pulling outward downward Then pull the grille straight out to completely remove it Cleaning Clean the cabinet at regular intervals Don t use de...

Page 9: ...utomatically when the door is opened Before replacing the light bulb disconnect the power plug from the outlet Cut the packaging around the bulb socket Keep the packaging on to hold the bulb when setting it into the socket Do not touch the bulb with your bare fingers Halogen light bulbs are sensitive to grease from the skin Use a clear halogen light bulb When the appliance is not in use Disconnect...

Page 10: ...e that the door is completely closed and that the insulating strip is complete and clean The temperature where the cabinet is placed is above normal room temperature The cabinet does not operate at all Cooling or interior light does not operate No indicator lamps light The cabinet is not switched on Power does not reach the cabinet Try connecting another electrical device to the power outlet The f...

Page 11: ...1600 mm Depth 600 mm Energy consumption 172 kWh year Energy class A Rated power 100 W Freezing capacity 24 kg 24 hours Installation GB Mains Cable Do not remove the power cord by pulling on its lead particulary when the product is being pulled out of its niche Damage to the cord may cause a short circuit fire and or electric shock In the event of damage to the appliance s main cable only an author...

Page 12: ...abinet is level The cabinet should not lean against any wall If necessary adjust the feet using the adjustment spanner supplied there is good air circulation around the cabinet and that the air channels below and behind the cabinet are not blocked The ventilation space above the cabinet must be at least 4 cm The ventilation space can either be a directly above the cabinet or b behind and above the...

Page 13: ...closing fitting 6 a Remove the door closing fitting from the bottom of the door b Then secure the supplied door closing fitting on the other side c Secure the lower hinge Remove any play in the door by adjusting the height of the lower hinge with the supplied spanner Secure with the lock nut 7 Raise the cabinet and replace the ventilation grille 8 To transfer the handle Unscrew the screws Fit the ...

Page 14: ...ÖäáÉI ëéáê éçäîÉêÉI ãçíçëÉÖÜÉ É ê ë ÉêÄ F îÉåÖçåç îÉåÇìíÉ çÖåá ååç áå éáìD Çá NRM m Éëá ÇÉä ãçåÇç éÉê ìå î äçêÉ Çá ÅáêÅ NQ ãáäá êÇá Çá Ççää êáK aáÉ bäÉÅíêçäìñJdêìééÉ áëí ÇÉê ïÉäíïÉáí Öê íÉ eÉêëíÉääÉê îçå Ö ëJ ìåÇ ëíêçãÄÉíêáÉÄÉåÉå dÉê íÉå ÑΩê ÇáÉ hΩÅÜÉI òìã oÉáåáÖÉå ìåÇ ÑΩê cçêëí ìåÇ d êíÉåK gÉÇÉë g Üê îÉêâ ìÑí ÇáÉ bäÉÅíêçäìñJdêìééÉ áå ΩÄÉê NRM i åÇÉêå ÇÉê bêÇÉ ΩÄÉê RR jáääáçåÉå mêçÇìâíÉ EhΩÜäëÅÜê ...