48
Electrolux 818 33 65-01/7
Before installing the cabinet
Affix the supplied plastic peaces at the rear of the
cabinet.
Cleaning
Wash the inside of the cabinet using lukewarm
water, a mild washing-up detergent and a soft cloth.
Installing the cabinet
When two appliances are placed beside each other,
the distances enclosed in the plastic wrapping should
be glued between the appliances. As shown in the
illustration.
Make sure that the power plug is not squashed or
damaged by back of the product.
·
A damaged power plug may overheat and cause a
fire.
Do not place heavy articles or the product itself on
the power cord.
·
there is a risk of a short circuit and fire.
If the power plug socket is loose, do not insert the
power plug.
·
there is a risk of electric shock or fire.
To obtain the best performance from the cabinet,
ensure :
·
the cabinet is placed in a dry, cool place and
is not exposed to direct sunlight.
·
the cabinet is not placed close to a source of
heat, e.g. a cooker or dishwasher.
·
the cabinet is level. The cabinet should not lean
against any wall. If necessary adjust the
feet using the adjustment spanner supplied.
·
there is good air circulation around the cabinet
and that the air channels below and behind
the cabinet are not blocked. The ventilation
space above the cabinet must be at least 4 cm.
The ventilation space can either be
a) directly above the cabinet, or
b) behind and above the top cupboard. In this case,
the space behind the cupboard must be at least
50 mm deep.
Cabinet is placed at a location whose ambient
temperature corresponds to the climate
classification*, for which the appliance is designed.
* See on the rating plate on the inside of the
appliance.
The following table shows which ambient
temperature is correct for each climate classification.
Climate
classification
for an ambient temperature of
+10°C to +32°C
+16°C to +32°C
+18°C to +38°C
+18°C to +43°C
SN
N
ST
T
50mm
a)
b)
If the cabinet is placed in a corner and the side with
the hinges facing the wall, the distance between the
wall and the cabinet must be at least 230 mm to
allow the door to open enough so that the shelves
can be removed.
The power plug must be accessible after installation
of the cabinet.