TECHNICAL DATA
Dimension
Height
1540 mm
Width
595 mm
Depth
658 mm
Rising Time
15 h
Voltage
230 - 240 V
Frequency
50 Hz
The technical information are situated in the
rating plate on the internal left side of the
appliance and in the energy label.
INSTALLATION
Read the "Safety Information" carefully
for your safety and correct operation of
the appliance before installing the
appliance.
Positioning
Install this appliance at a location where the
ambient temperature corresponds to the
climate class indicated on the rating plate of
the appliance:
Climate
class
Ambient temperature
SN
+10°C to + 32°C
N
+16°C to + 32°C
ST
+16°C to + 38°C
T
+16°C to + 43°C
Location
The appliance should be installed well away
from sources of heat such as radiators,
boilers, direct sunlight etc. Ensure that air
can circulate freely around the back of the
cabinet. To ensure best performance, if the
appliance is positioned below an overhang-
ing wall unit, the minimum distance be-
tween the top of the cabinet and the wall
unit must be at least 100 mm . Ideally, how-
ever, the appliance should not be posi-
tioned below overhanging wall units. Accu-
rate levelling is ensured by one or more ad-
justable feet at the base of the cabinet.
Warning!
It must be possible to
disconnect the appliance from the
mains power supply; the plug must
therefore be easily accessible after
installation.
A
B
100 mm min
20 mm
Electrical connection
Before plugging in, ensure that the voltage
and frequency shown on the rating plate
correspond to your domestic power supply.
The appliance must be earthed. The power
supply cable plug is provided with a contact
for this purpose. If the domestic power sup-
ply socket is not earthed, connect the appli-
ance to a separate earth in compliance with
current regulations, consulting a qualified
electrician.
electrolux
23