1.4
WOEC test programmes and their application
The control is provided with various test programmes, some of which can be switched
on manually or run automatically in the background.
Safety cut-out
The appliance is equipped with a safety circuit which switches it off automatically if the
allocated time intervals are exceeded at various temperature settings without the
functions or temperature setting being changed. This time interval is smaller the higher
the selected temperature.
Examples:
up to 250 °C 3 h
up to 230 °C 6 h
up to 120 °C 12 h
Self-test
The automatic test programme which runs permanently in the background carries out a
self-test at regular intervals to monitor for correct operation of the appliance. If any
deviation from the specified parameters is detected during this test, the service symbol
and a 3-digit service code are shown in the display.
In addition, the appliance is switched on via safety relay K60 and the cooling fan via
K61.
The cooling fan cannot be switched off on the appliance as long as the above-
mentioned self-test detects the fault. The only possibility of switching off the cooling fan
is to remove the fuse in the house electrical installation.
Service test
The manual test system for the control comprises 6 test programmes. Access to these
6 test programmes is only possible if the control is in a fault mode and displaying the
current fault or the time is flashing.
This is achieved directly after connecting a voltage. If the test programmes are to be
accessed during operation, the appliance must be disconnected from the mains for at
least 10 s.