Range installation instructions
INSTALLATION INSTRUCTIONS FOR FREESTANDING DUAL FUEL
OR 3-Wire connection instructions
(for existing installations ONLY
See Fig. 34)
B
Power Cord Connection
1.
Follow the manufacturer’s installation instructions
supplied with the strain relief and install (Also see
Figs. 29, 30 & 31).
2.
Insert the end connectors for Line 1, Line 2 and Neutral
and tighten securely to the terminal block (See Fig. 34).
IMPORTANT NOTE:
DO NOT LOOSEN the factory
installed nut connections which secure the range
wiring to the terminal block. Electrical failure or loss of
electrical connection may occur if these 3 nuts are
loosened or removed.
3.
Make sure all connections are tightened securely and
replace the rear access cover (See Fig. 30).
Fig. 33
Grounding instructions (for 3-Wire
connections ONLY)
A ground strap is installed on this range which connects
the center terminal of the terminal block (neutral) to the
range chassis. The ground strap is connected to the range
by the center, lowest screw (See Fig. 34). The ground strap
must not be removed unless national or local codes do not
permit use of ground strap.
NOTE:
If the ground strap is removed for any reason, a
separate ground wire must be connected to the separate
ground screw attached to the range chassis and to an
adequate ground source.
Fig. 34
For 3 & 4-Wire permanent connections ONLY
3 - Wire permanent connection - follow Steps
1,2 & 5 below.
4 - Wire permanent connection - follow Steps
1 thru 5 below.
Before wiring the range, review the suggested power
source location drawings in Fig. A & B. If connecting to a
4-Wire electrical system (new branch-circuit or mobile
home requires 4-Wire connection):
1.
(3 & 4 - Wire permanent connections)
Follow the
manufacturer’s installation instructions supplied with
the strain relief and install.
8