Cabinet and countertop dimensions
•
Check for wall and cabinet clearances where the range will be installed.
•
Check the stability of the floor where the range will be installed.
•
Check for proper electrical and gas supply.
Note: All dimensions provided are minimal unless otherwise stated.
To eliminate the risk of burns
or fire by reaching over
heated surface units, cabinet
storage space located above
the surface units should be
avoided. If cabinet storage is
to be provided, the risk can
be reduced by installing a
range hood that projects
horizontally a minimum of 5”
beyond the bottom of the
cabinets.
INSTALLATION INSTRUCTIONS FOR FREESTANDING DUAL FUEL
•
Do not seal the range to side cabinets.
•
Do not pinch the power supply cord between the
range and the wall.
•
If cabinet depth is greater than 25”, the oven front
frame must extend beyond cabinet front by 1/2”
minimum.
All openings in the wall or floor where the range is
to be installed must be sealed.
Install a flush mount
240V 40/50 ampere
electrical wall outlet
in the shaded area.
This shaded floor
area is for thru the
floor connection of
gas pipe stub and
shut-off valve.
Add 1/2” NPT 90°
black pipe elbow to
the gas supply pipe
stub and orient the
elbow as shown.
** Please note: The gas supply pipe stube and
elbow assembly centerline should not exceed
4” height from the floor.