Anti-tip bracket installation instructions
INSTALLATION INSTRUCTIONS FOR FREESTANDING DUAL FUEL
Fig. 24
Fig. 27
Fig. 25
Fig. 26
Electrical requirements
Fig. 28
Electrical connection requirements
Models Requiring Power Supply Cord Kit
RISK OF FIRE OR ELECTRICAL SHOCK MAY OCCUR IF AN
INCORRECT SIZE RANGE CORD KIT IS USED, THE
INSTALLATION INSTRUCTIONS ARE NOT FOLLOWED OR
STRAIN RELIEF BRACKET IS DISCARDED.
This appliance may be connected by means of a power
supply cord. Only a power supply cord kit rated at 125/250
volts minimum, and marked for use with ranges shall be
used. See chart (Fig. 29) for cord kit ampere rating information.
Cord must have either four (4) or three (3) conductors (See Fig.
28). Terminals on end of wires must be either closed loop or
open-end spade lugs with upturned ends. Cord must have
strain relief clamp. See Step B in Installation Steps for 4 or
3 - Wire connections.
This appliance must be properly installed and grounded by
a qualified technician in accordance with the National Electrical
Code ANSI/NFPA No. 70 -- latest edition -- and local electrical
code requirements.
This appliance may be connected by means of permanent
"Hard Wiring" or "Power Supply Cord Kit."
When hard wiring, do not leave excess wire in range
compartment. Excess wire in the range compartment may not
allow the access cover to be replaced properly, and could
create a potential electrical hazard if wires become pinched.
Connect only as instructed under "WIRING INSTRUCTIONS"
in Step B of the Installation Steps. When using flexible conduit
or range cable use flex connector or range cable strain relief
(See Fig. 32 on page 7).
NOTE:
Only use copper wire in connection to terminal block.
3 & 4 - Wire electrical wall Receptacle types &
recommended mounting orientation on wall
Required for new and
remodeled installations
4-Wire Wall
receptacle (14-50R)
Allowed for
existing installations
3 Wire Wall
receptacle (10-50R)
6