background image

Summary of Contents for EW30DF65GBA

Page 1: ...Installation Instructions lnstrucciones para instalar O_ s D _ _ 30 ...

Page 2: ... supply and the stability of the floor Dimensions that are shown must be used Given dimensions provide minimum clearance Contact surface must be solid and level Refer to your serial plate for applicable agency certifications Provide Proper Fuel Type Before Proceeding Your range is preset to operate on Natural Gas only Important Note to the Consumer Keep these instructions with your Use Care Guide ...

Page 3: ...or covering can withstand heat at least 90 F above room temperature without shrinking warping or discoloring Do not install the range over carpeting unless you place an insulating pad or sheet of 1 4 inch thick plywood between the range and carpeting Make sure the wall coverings around the range can withstand the heat generated by the range Do not obstruct the flow of combustion air at the oven ve...

Page 4: ...of LP Propane gas Fig 15 Gas line manual shut off valve Fig 16 1 2 NPT 90 black pipe elbow Fig 17 A new flexible metal appliance conduit 1 2 NPT x 3 4 or 1 2 I D must be design certified by CSA International Fig 18 Because solid pipe restricts moving the range we recommend using a new flexible conduit 48 MAXIMUM LENGTH for each new installation and additional reinstallations Always use the 2 new f...

Page 5: ... unless otherwise stated 18 13 Minimum J Fig A 2 1 4 Back Wall Fig B Install a flush mount 240V 40 50 ampere electrical wall outlet in the shaded area Do not seal the range to side cabinets Do not pinch the power supply cord between the range and the wall If cabinet depth is greater than 25 the oven front frame must extend beyond cabinet front by 1 2 minimum All openings in the wall or floor where...

Page 6: ...d does not allow the bracket to fit flush against wall remove molding or mount bracket to floor For wall mount Fig 24 locate the bracket by placing the back edge of the template against rear wall and the side edge of template on the mark made referencing the side of the range Place bracket on top of template and mark location of the screw holes in wall If rear of range is further than 1 1 4 from w...

Page 7: ...excess wire in range compartment Excess wire inthe range compartment may not allow the access cover to be replaced properly and could create a potential electrical hazard if wires become pinched Connect only as instructed under WIRING INSTRUCTIONS in Step Bof the Installation Steps When using flexible conduit or range cable use flex connector or range cable strain relief See Fig 32 on page 7 NOTE ...

Page 8: ...circuit or mobile home requires 4 Wire connection Power cord instructions 1 Followthemanufacturer sinstallationinstructions supplied with the strain relief and install Also see Figs 29 30 31 32 2 Insert the end connectors for Line 1 Line 2 and Neutral and tighten securely to the terminal block IMPORTANT NOTE DO NOT LOOSEN the factory installed nut connections which secure the range wiring to the t...

Page 9: ...a separate ground wire must be connected to the separate ground screw attached to the range chassis and to an adequate ground source For 3 4 Wire permanent connections ONLY 3 Wire permanent connection follow Steps 1 2 5 below 4 Wire permanent connection follow Steps 1 thru 5 below Before wiring the range review the suggested power source location drawings in Fig A B If connecting to a 4 Wire elect...

Page 10: ... Cut and discard the copper strap from the terminal block KEEP the ground screw ground plate and go to Step 4 4 4 Wire Permanent Connection ONLY Connect the ground wire lead Green to the frame of the appliance using the ground screw plate as shown in Fig 36 Be sure to install using the same hole in the frame where the ground screw was originally installed 5 3 4 Wire Permanent Connections Make sure...

Page 11: ...em during any pressure testing of that system at test pressures greater than 14 of water column pressure approximately 1 2 psig The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 14 of water column pressure approximately 1 2 psig Seal the...

Page 12: ...pply line connectors have been carefully checked for leaks and range has been connected to electric power 1 To check for proper lighting push in and turn surface burner knob counterclockwise to the _ lite position You will hear the igniter sparking Fig 39 2 The surface burner should lightwhen gas is available to the top burner Purge air from supply lines by knob in the _ lite position until burner...

Page 13: ...e Care Guide for cleaning instructions If removing the range is necessary for cleaning or maintenance shut offthe gas supply Disconnect the gas and electrical supply If the gas or electrical supply is inaccessible liR the range slightly at the front and pull out away from the wall Pull only as far as necessary to disconnect the gas and electrical supply Finish removing the range for servicing and ...

Page 14: ...I_ Ele ...

Reviews: