Dishwashers
EWDW6505G S, EWDW6505G W, EWDW6505G B
High standards of quality at Electrolux Major Appliances mean we are
constantly working to improve our products. We reserve the right to change
specifications or discontinue models without notice.
USA
•
250 Bobby Jones Expressway
•
Augusta, GA 30907
•
1-877-4electrolux (1-877-435-3287)
•
electroluxappliances.com
CANADA
•
5855 Terry Fox Way
•
Mississauga, ON L5V 3E4
•
1-800-265-8352
•
electroluxappliances.ca
EWDW6505G 02/08
© 2008 Electrolux Major Appliances, NA
Printed in the U.S.A.
3
1
/
2
" min.to
4
1
/
2
" max.
1
3
/
4
"
1
3
/
4
"
1
3
/
4
"
**NOTE:
35" max. height for
standard cabinetry cutout.
(
1
/
4
" min. clearance
required from unit to
underside of countertop.)
3"
18"
24"
min.
Electrical, water,
and drain lines
must be confined
to shaded area.
1
3
/
4
"
24"
3"
90
°
90
°
Preferred
Drain Areas
3"
34"
min.
to
35"
max.**
Water inlet and power supply
location (middle bottom rear)
49
7
/
8
"
22
1
/
2
"
Right
Door in 90
°
open position
27
3
/
8
"
24
5
/
8
"
Left
Front
*Height only adjustable to 34
3
/
4
" max. when
installed in 35" max. standard cabinetry cutout.
33
7
/
8
"
Adjustable
to 34
7
/
8
"*
23
3
/
4
"
Built-In Dishwasher Specifications
•
Product Weight – 98 Lbs.
•
Voltage Rating – 120V / 60 Hz / 15 Amps
•
Connected Load (kW Rating) @ 120 Volts = 1.44 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded for
safe operation.)
•
Amps @ 120V = 9 Amps
•
Always consult local and /or national electric & plumbing codes.
•
Water Pressure – Hot water line to dishwasher must provide between
15 and 120 pounds per square inch (psi).
•
Make sure location has right drain, water and electrical outlets to make
connections.
•
Keep back free of drain, water & electrical supply.
•
Electrical and water supplies should enter cabinet opening on floor,
or through back or side walls, as shown in shaded areas.
•
Connections preferably located toward left side of dishwasher. Do not
cross drain, water or electrical lines in front of motor, blower or frame.
•
Minimum clearance of 1/4" required from unit to underside of countertop.
•
Leveling legs supplied to adjust height.
(Note: Height only adjustable to
34-3/4" max. when installed in 35" max. standard cabinetry cutout to
allow for 1/4" min. clearance.)
•
When installing in corner, allow 2" clearance between opened door and
wall, to allow door to open.
•
When installing at end of cabinet line, sides must be fully enclosed.
•
Do not install unit under a cooktop, damage may occur.
Note: For planning purposes only. Refer to Product Installation Guide