Position 6
No command
Purpose of the test:
-------------
Components activated:
-------------
Working conditions:
-------------
LCD display
Position 7
Heating
Purpose of the test:
To check the correct operation of the heater unit.
Components activated:
•
Door fastening device.
•
Wash solenoid, if the water in the tub is not
enough to cover the heating element.
•
Heating
element.
Working conditions:
•
Door
closed
•
Water level high enough to cover the heating
element.
•
Maximum time 10 mins up to 90
°
C.
(*)
LCD display
Temperature in °C measured using the
NTC probe.
Position 8
Leaks from the tub
Purpose of the test:
To check for any water leaks from the tub during
operation.
Components activated:
•
Door fastening device.
•
Wash solenoid, if the water in the tub is not
enough to cover the heating element.
•
Motor (anticlockwise rpm, pulse at 250 rpm).
Working conditions:
•
Door
closed.
•
Water level above
•
The heating element.
LCD display
Drum speed in rpm/10