SOI/DT 2002-07 eb
17
599 35 36-69
5.2 Cotton / Linen Cycles: 90 Eco, 60 - 40/50 “energy label” (without options)
Phase
N.
Function
Time /
control
Movement
Heat.
°
C
Notes
Delay
- Delayed start
Delay time
No Mov
Drain
0 Drain
VAE + 2”+
6” pause
No Mov
1 Water fill
P1 + QPW1 (*)
2 Cold
wash
5’
D55 from full
Refill:
P1
3 Water fill
QPW2 (*)
4 Heating
T
30 Cold = 20
°
C
5 Movement
10’
D55
6 Drain
VAE + 14”
No Mov
7 Drain + spin
4,5’
C0
300/450/650 rpm
P
re-
w
a
sh
8 Drain
20”
No
Mov
9 Cotton water fill
P1 + Qe (*)
10 Cold
wash
10’
N55 from full
Refill:
P1+Qwe
11 Heating
T
N55
67/53/44
12 Maintenance
10’(67
°
) / 5’(53
°
)
/ 40’(44
°
)
E55
67-64/----
/44-40
12a Movement 40/50
15’
N55
Only with 44
°
C
13 Cotton heating
T
E55
67/53/44
14 Movement
30’(67
°
) /
35’(53
°
)/20’(44
°
)
E55
N55
with
67
°
C
15 Drain
VAE + 14”
No Mov
16 Drain + spin
5’
C1
450/650/850 rpm
Wa
sh
17 Drain
20”
No
Mov
18 Cotton
water
fill
P1
19 Movement
5’
N 55 from full
Refill:
P1+Qne
20 Drain
VAE + 15”
No Mov
21 Drain + spin
5’
C2
450/650/850/1000
rpm
1st
rinse
22 Drain
20”
No
Mov
23 Cotton
water
fill
P1 if C1
≥
850 rpm
P1+Qn2 (*) if
C1<850 rpm)
24 Movement
5’
N 55 from full
Refill:
P1+Qne
25 Drain
VAE + 15”
No Mov
26 Drain + spin
5’
C2
450/650/850/1000
rpm
2nd
rinses
27 Drain
20”
No
Mov
28 Cotton
water
fill
P1
29 Movement
30”
30 Time
water
fill
Qn3
31 Movement
8’
N 55 from full
Refill:
P1
32 Drain
VAE + 14”
No Mov
33 Drain + spin
9’
COT_CF
450/650/850/1000
rpm
R
in
s
es
Last rinse
(softener)
34 Untangling
1’
N55
SW W1D00104
Notes:
P1
time needed to 1
st
level water fill
(*)
time water fills are changeable and calculated by the electronic on the basis of the delivery rate
(see specific table)
T
time needed to heat the water at the set temperature
”
seconds
‘
minutes
VAE
time needed to drain the water till “empty” position of anti-boiling (safety heater) pressure
switch
Movement
: this column describes the drum movements at low speed and during spin (see paragraph
“drum movements”). The length of drain phases with spin cycle is approximate and does not
take into consideration the antiunbalance and antifoam safety systems.