Guide to diagnostics of electronic controls EWM10931
2011 SOE/DT-mdm FCPD-dp Quality tb
13/75
599 73 77-37
5 OPERATING TIME COUNTER
Using a specific procedure, the operator can display the total operating time for the appliance, which is
counted from the moment it is first switched on.
The unit can count up to a maximum of
6,550
hours of operating time.
Only the operating time of normal programmes (and not diagnostic cycles) is counted
The actual operating time for the cycle is counted (which does not include pauses, delayed start time,
rinse hold time and soaking phases)
The precision of the counter is 30 seconds per programme
Only whole hours of operation are counted (1hr and 59 min = 1hr)
5.1 Reading the operating time
Do not start the procedure with the combination buttons pressed
1. Turn the appliance on at the ON/OFF switch.
2. Turn the selector dial clockwise until the
fifth
LED in the right-hand row is on.
3. Press
the
START/PAUSE
button and the nearest
option
button
simultaneously (as shown in the figure).
4. Hold down the buttons until the hours of operation appear on the display (at least 5 seconds).
5.2 Display of total operating time
This time is displayed with a sequence of two digits at a time: the first two digits indicate thousands and
hundreds, the second two digits indicate tens and units for the SERIES 7 and 8, while the time is displayed
in a single sequence for SERIES 9.
For example, if the operating time is
6,550
hours, the display will show the following sequence:
Phase 1
Phase 2
Phase 3
For two seconds, the
following is displayed: Hr
For two seconds, the
following digits are
displayed:
ª
thousands
(
6
)
ª
hundreds
(
5
)
For the next two seconds
the following digits are
displayed:
ª
tens
(
5
)
ª
units
(
0
)
SERIES
7/8
Phase 1
Phase 2
SERIES
9
At the end of phase three (after the tens and units are displayed), the cycle is repeated.
To return to normal mode, either: switch the appliance off or press a button or turn the selector knob.