Guide to diagnostics of electronic controls EWM10931
2011 SOE/DT-mdm FCPD-dp Quality-tb
55/75
599 73 77-37
Run the diagnostic cycle
and fill with water up to the
door level to make sure the
heating element is
completely submerged.
Measure between the wiring
connector J3-1/J3-2 and the
appliance body.
-(see fig.6)-
Is the circuit open?
E68
E68: Washing heating element leakage
E68
Checks to perform:
Detach the connectors
and measure between
the heating element
and the earth contact.
-(see fig.19)-
Is the circuit open?
Run phase
9
of the
diagnostic cycle, drain water
from the tub. Replace the
heating element and repeat
the diagnostic cycle to
check for any further alarms.
Check/replace the wiring and repeat the diagnostic cycle to
check for any further alarms.
Replace the main circuit
board and repeat the
diagnostic cycle to check for
any further alarms.
Y
E
S
NO
NO
Y
E
S
J16 J13 J15
J10
J11
J4
J8
J7
J6
J12
J5
J3
J9
J1
Fig. 4
Fig. 6
Check that all the connectors are correctly inserted
!
If there are burns on the circuit
board, see page 73
!
Fig. 19
MAIN CIRCUIT
BOARD
Washing heating element
∞ Ω
∞
Ω
∞
Ω