5.6 Notes concerning certain alarm codes
Configuration alarms
E93
:
If these alarms are generated (when the appliance is switched on), operation of the appliance is blocked and all the LEDs light.
The diagnostic procedure cannot be accessed; the only option is to switch the appliance OFF (by turning the selector to position “0”).
Configuration alarm
E94
:
For this alarm code, only the family for alarm “9” is displayed; the diagnostic procedure cannot be accessed, and the “rapid alarm
display” function cannot be used.
Alarms
EH1-EH2-EH3
:
In the event of problems with the mains power supply, the appliance remains in alarm mode until the mains frequency or voltage are
restored to the correct value or the appliance is switched off (by turning the programme selector to “0”). The family of alarm “B” is displayed; the diagnostic
procedure cannot be accessed, and the “rapid alarm display” function cannot be used. The complete alarm code can be read only when the abnormal
situation has ceased.
Alarms
E51- E52
:
During the diagnostic test, all the alarms are displayed. Normally, when the programme selector is turned from one test phase to another,
the appliance exits the alarm condition and performs the phase selected. This does not take place in the case of alarms E51 (power triac on motor short-
circuited) and E52 (no signal from the tachometric generator on the motor): in these cases, the only option to exit the alarm condition is to switch the appliance
OFF by turning the selector to position “0” (reset).