E21: Difficulties in draining
E21
Maximum drain time exceeded (measured for each phase of the cycle)
E21
Tests to be performed:
YESI
YES
NO
Clean the filter and restart the diagnostic cycle
to check for further alarm conditions.
Is the drain filter clean?
NO
Disconnect and check the drain system.
Is the drain system OK? (drain hose and
domestic hydraulic circuit)-
fig.1
Does the drain
pump function? (in
the diagnostic cycle,
select
phase 2
fill and
phase 8
drain) (noise
from the pump)
Is the ohmic
resistance of the
pump about 155-
200
Ω
? (measure
directly on the
connector on the
circuit board side
across J7-9 and J7-
1)
-fig. 4-
Replace the pump
and restart the
diagnostic cycle to
check for further
alarm conditions.
Is the ohmic
resistance of the
pump about 155-
200
Ω
? (measure
directly on the
pump)
-see
fig.5
-
YES
Check and if necessary replace the wiring and
restart the diagnostic cycle to check for further
alarm conditions.
Is the pump
impeller jammed or
broken?
Is the hydraulic circuit of the pressure switch
efficient? (i.e. not obstructed)
Replace the circuit board and restart the
diagnostic cycle to check for further alarm
conditions.
Repair the hydraulic circuit of the pressure
switch and restart the diagnostic cycle to check
for further alarm conditions.
Clean or replace the drain pump and restart the diagnostic cycle to check
for further alarm conditions.
Replace the pressure switch and restart the
diagnostic cycle to check for further alarm
conditions.
YES
YES
YES
If there are traces of burning on the
circuit board, refer to page
59