26/59
599 70 32-47
Drain the water from the tub.
Are pressure switch hose and air trap
system free? (You can disconnect the
hose and blow in it to check if the
system is free)
fig. 2 and 8
YES
E32
The analogic pressure switch is giving an error during the calibration
phase
(At the beginning of each cycle the appliance drain to empty the tub
and create a 0 level to verify the calibration of the analogic pressure switch)
E32
Tests to be performed:
NO
Clean/change the hoses and/or air trap
system and repeat completely the
diagnostic cycle to check for further
alarm conditions.
Select a washing cycle. After few
minutes did the machine fill with water
and the motor is turning?
Check the draining system (filter,
drain pump, drain hose). Is the
machine draining correctly?
Clean the draining system.
Appliance is OK.
Replace the analogic pressure switch
and run again the diagnostic cycle to
check for further alarm conditions.
YES
YES
YES
NO
NO
fig. 8
Fig.2
If there are traces of burning on the
circuit board, refer to page
59