2007-10 SOI/DT-mdm FCPD-dp Quality-fz
28/59
599 70 32-47
Get inside the
diagnostic cycle and
go to
step 6
. Is the
motor turning and
the drum not
moving?
YES
Empty the machine.
Verify the air trap
system and the
pressure switch
hoses. Is the system
free?
-see fig.2-
Clean the air trap
system and/or the
pressure switch
hose and run again
the diagnostic cycle.
Change/refit the
drive belt and run
again the diagnostic
cycle to check for
further alarm
conditions.
SI
Measure across
connector J7-2 and
the machine
structure and across
connector J7-8 and
the machine
structure, are there
any current
leakage?
-see fig.6-
Replace the
analogic pressure
switch and run again
the diagnostic cycle
to check for further
alarm conditions.
Check/replace the
wiring and run the
diagnostic cycle
again to check for
further alarm
conditions.
E38: Pressure chamber blocked
E38
The analogic pressure switch is not able to measure any variation of the water level for at
least 30-sec. during drum movement.
E38
Tests to be performed:
Fig.2
NO
NO
If there are traces of burning on
the circuit board, refer to page
59
J9
J10
J7
J2 J1
U3
Fig.4
fig. 6
NO
YES