E51: Motor power triac short-circuited
E51
Intervention of the safety system for short-circuiting of the triac (after 5 attempts during the
cycle, immediately if detected at the start or during diagnostics)
E51
Tests to be performed:
YES
YES
Measure among all the
terminals of wiring connector
J7-2÷J7-8 and the structure
of the appliance
see fig.6
Is there current leakage?
Detach the connector from
the motor and measure
across the terminals of the
motor and the motor shield.
-see fig.10-
Is there current leakage?
Reconnect the connector J7 to
the circuit board, detach the
connector from the motor and
perform
phase 8
of the
diagnostic cycle.
Does E51 alarm appear again?
Replace the circuit board and
restart the diagnostic cycle to
check for further alarm conditions.
Check/replace the wiring and
restart the diagnostic cycle to
check for further alarm
conditions.
E52 will probably be
displayed: replace the
motor and restart the
diagnostic cycle to check
for further alarm
conditions.
fig. 10
YES
Replace the motor and
restart the diagnostic cycle
to check for further alarm
conditions.
If there are traces of burning on the
circuit board, refer to page
59