E71: NTC washing sensor faulty
E71
Voltage not within limits (short-circuited or open)
E71
Tests to be performed:
fig. 14
Perform
phase 6
of the diagnostic
cycle and wait until the fill ends. Switch
the appliance off and measure the
value of the NTC sensor across
contacts J9-8 and J9-9 dof the wiring
connector
-see fig. 4-.
Is the value correct?
(between 5.7÷6.3 K
Ω
at 20°C)
Detach the connector
and measure the NTC
sensor directly.
- see fig. 14 -
Is the value correct?
(5.7
÷
6.3 K
Ω
at 20°C)
Replace the NTC
sensor and restart the
diagnostic cycle to
check for further
alarm conditions.
Measure across terminals J9-9, J9-8 of
the connector and the structure of the
appliance
– see fig. 6 -
Is there any current leakage?
Check/replace the wiring and restart the diagnostic
cycle to check for further alarm conditions.
Detach the connector and measure
directly across the terminals of the NTC
sensor and the structure of the appliance
(there must be water in the tub).
Is there any leakage?
Replace the NTC sensor and restart the
diagnostic cycle to check for further
alarm conditions.
Replace the circuit board and restart the diagnostic
cycle to check for further alarm conditions.
Check/replace the wiring and restart the diagnostic
cycle to check for further alarm conditions.
If there are traces of burning on the circuit
board, refer to page
59
J9
J10
J7
J2 J1
U3
Fig.4
fig. 6
Circuit
board