EA6: Drum flap faulty (top-loaders)
EA6
Cycle immediately blocked if a not correct tachometric signal is identified for at least 3
seconds.
EA6
Tests to be performed:
fig. 10
Open the door and
manually check if
the drum turns
easily.
Is the drum
blocked?
Measure across the
terminals of the wiring
connector J7-7 and J7-
8.
Are the values (
Ω
) of
the tachometric
generator correct?
(see
page 39
- Step 4, phase “A” ).
YES
Replace the drum
flap and restart the
diagnostic cycle to
check for further
alarm conditions.
YES
Detach the connector
from the motor and
measure (
Ω
) the coil
of the tachometric
generator
-see fig.11-
Is the value correct?
(see
page 39
- Step 4, phase “A” ).
YES
Check/replace the wiring and restart the
diagnostic cycle to check for further alarm
conditions.
Replace the
motor or the
tachometric
generator and
restart the
diagnostic cycle
to check for
further alarm
conditions.
Measure across the
same terminals of the
wiring connector (J7-7
and J7-8) and the
structure of the
appliance.
Is there any leakage?
- see fig.6 -
.
Check for the
positioning of the
tachometric
generator.
Is it correct?
- see fig.12 -
Replace the main circuit board and restart the
diagnostic cycle to check for further alarm
conditions.
Replace the
motor/ generator
and restart the
diagnostic cycle
to check further
alarm conditions.
Check/replace the wiring and restart the diagnostic
cycle to check for further alarm conditions.
YES
YES
fig. 6
180
Ω
∞
Ω
Circuit
board
180
Ω
∞
Ω
If there are traces of burning on the
circuit board, refer to page
59
fig. 11
fig. 12