SOI/DT 2007-02 dmm
36/66
599 38 61-92
The alarms are enabled during the execution of the washing programme, with the exception of alarms
associated with configuration and the power supply (voltage/frequency), which are also displayed during the
programme selection phase.
The door can normally be opened (except where specified) when an alarm condition has occurred on condition
that:
•
The level of the water in the tub is below a certain level
•
Water temperature lower than 55
°
C
•
Motor
stopped
Certain alarm conditions require that a drain phase be performed before the door can be opened for safety
reasons:
•
Cooling water fill if the temperature is higher than 65
°
C
•
Drain until the analogue pressure switch is on empty, during a max. 3-minute time.
6.2
Reading the alarm codes
It is possible to display the last three memorised alarms in the FLASH memory of
the electronic board:
•
Enter diagnostic mode (par. 5.1).
•
Irrespective of the type of PCB and configuration, turn the programme selector
clockwise
to the
tenth position.
•
The last alarm is displayed.
•
To display the previous alarms, press button
TEMPERATURE (1) or SPIN (2).