SOI/DT 2007-02 dmm
59/66
599 38 61-92
Alarm
Possible fault
Action/machine status
Reset
EH1
Power supply problems (incorrect / disturbance); PCB faulty.
Wait for frequency nominal conditions.
OFF/ON
EH2
Power supply problems (incorrect / disturbance); PCB faulty.
Wait for voltage nominal conditions.
OFF/ON
EH3
Power supply problems (incorrect / disturbance); PCB faulty.
Wait for voltage nominal conditions.
OFF/ON
EHE
Wiring faulty; PCB faulty.
Safety drain cycle – Cycle stopped with door open.
RESET
EHF
PCB faulty.
Safety drain cycle – Cycle stopped with door open.
RESET
EC1
Solenoid valve faulty/blocked; PCB faulty.
Cycle interrupted with door closed.
Drain pump functions always (5 min., then it stops for 5
min. etc.)
RESET
EC3
Wiring faulty; Weight sensor faulty; PCB faulty.
----------------
START/RESET
EF1
Drain tube blocked/kinked/too high;
Drain filter dirty/blocked.
Warning displayed at the end of cycle (specific LED).
START/RESET
EF2
Excessive detergent dosing; drain tube kinked/blocked;
Drain filter dirty/blocked.
Warning displayed after 5 attempts or by the specific
LED.
RESET
EF3
Water leaks onto base frame; water control system defective.
Machine drains and cycle stops
ON/OFF RESET
EF4
Tap closed, water pressure too low
---------------------------
RESET
EF5
Final spin phases skipped.
---------------- RESET
E00
---------------- ----------------
----------------