ENGLISH
15
refrigerant circuit because the circuit
operating temperature is high.
r© 4HE©PIPES©CONNECTING©THE©INDOOR©AND©
outdoor unit are not included in the
unit.
r© 4HE©OUTDOOR©UNIT©IS©POWERED©BY©THE©
indoor unit.
Installation site
r© $O©NOT©INSTALL©THE©UNIT©IN©AREAS©WITH
© STRONG©HEAT©SOURCES
© VAPOURS©OR©lAMMABLE©GASSES
© CONTAMINATION©WITH©OIL©PARTICLES
- high frequency electromagnetic
equipment (e.g. welding equipment or
MEDICAL©DEVICES
- high salinity (e.g. close to coastal
AREAS
© SULPHURIC©GAS©EG©HOT©WATER©SPRINGS
- poor air quality.
Indoor unit
r© -AINTAIN©THE©MINIMUM©INSTALLATION©
distances specified in this document.
Do not block the air inlet or the air
outlet.
r© $O©NOT©USE©THE©UNIT©IN©PLACES©WITH©
extremely high humidity.
r© )NSTALL©THE©INDOOR©UNIT©OUT©OF©REACH©OF©
children.
r© 4HE©WALL©MUST©BE©STRONG©ENOUGH©TO©
support the weight and vibration of
the unit.
r© )NSTALL©THE©INDOOR©UNIT©AT©LEAST©
23
©CM©
above the floor surface.
r© ,EAVE©SUFkCIENT©SPACE©FOR©CLEANING©
and maintenance.
r© 4HE©AIR©kLTER©SHOULD©REMAIN©ACCESSIBLE©
r© ,EAVE©AT©LEAST©©M©DISTANCE©
between the unit and other electrical
appliances.
r© )NSTALL©THE©INDOOR©UNIT©IN©A©PLACE©WHERE©
the condensate water can be easily
drained.
r© )NSTALL©AT©A©LOCATION©PROTECTED©FROM©
direct sunlight.
Outdoor unit
r© -AINTAIN©THE©MINIMUM©INSTALLATION©
distances specified in this document.
r© $O©NOT©BLOCK©THE©AIR©INLET©OR©THE©AIR©
outlet.
r© )NSTALL©THE©OUTDOOR©UNIT©OUT©OF©REACH©OF©
children.
r© )NSTALL©THE©OUTDOOR©UNIT©WHERE©THERE©IS©
sufficient ventilation.
r© )NSTALL©THE©OUTDOOR©UNIT©WHERE©
produced noise and airflow will not
disturb neighbors or animals.
r© )NSTALL©THE©OUTDOOR©UNIT©IN©A©DRY©PLACE©
r© )NSTALL©THE©OUTDOOR©UNIT©IN©A©PLACE©NOT©
exposed to direct sunlight or strong
wind.
r© )NSTALL©THE©UNIT©IN©A©PLACE©THAT©SUPPORTS©
the weight and vibration of the unit.
r© 4HE©HEIGHT©DIFFERENCE©BETWEEN©THE©
indoor unit and the outdoor unit must
be less than 5 m.
r© 4HE©LENGTH©OF©THE©CONNECTING©PIPES©
must be less than 10 m.
r© ,EAVE©SUFkCIENT©SPACE©FOR©CLEANING©
and maintenance.
r© 4HE©OUTDOOR©UNIT©IS©POWERED©BY©THE©
indoor unit.
Safety precautions for electrical
appliances
r© 5SE©A©DEDICATED©MAINS©CIRCUIT
r© 4HE©UNIT©MUST©BE©PROPERLY©GROUNDED
r© )NSTALL©A©2ESIDUALCURRENT©DEVICE©
(RCD) to protect against personal
injury in case of leakage currents.
r© 5SE©AN©ALL©POLE©DISCONNECTION©SWITCH©
with a contact separation of at least
3 mm in all poles in fixed wiring. For
models with a mains plug, make sure
that the mains plug is within reach
after installation.
r© 4HE©INSTALLATION©MUST©COMPLY©WITH©
local electrical safety regulations and
with other relevant local regulations
r© 4HE©UNIT©MUST©BE©INSTALLED©IN©
accordance with national wiring
regulations.